| поискавой системы для электроныых деталей |
|
AD9956/PCB датащи(PDF) 31 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9956/PCB датащи(HTML) 31 Page - Analog Devices |
|
31 / 32 page ![]() AD9956 Rev. 0 | Page 31 of 32 CFR2<15:12> PLLREF Divider Control Bits (÷M) These 4 bits set the PLLREF divider (÷M) ratio where M is a value equal to 1 to 16. CFR2<15:12> = 0000 means that M = 1 and CFR2<15:12> = 1111 means that M = 16, or simply, M = CFR2<15:12> + 1. CFR2<15:12> = M = CFR2<15:12> = M = 0000 1 1000 9 0001 2 1001 10 0010 3 1010 11 0011 4 1011 12 0100 5 1100 13 0101 6 1101 14 0110 7 1110 15 0111 8 1111 16 CFR2<11:8> PLLREF Divider Control Bits (÷N) These 4 bits set the PLLOSC divider (÷N) ratio where N is a value equal to 1 to 16. CFR2<11:8> = 0000 means that N = 1 and CFR2<11:8> = 1111 means that N = 16, or N = CFR2<11:8> + 1. CFR2<15:12> = N = CFR2<11:8> = N = 0000 1 1000 9 0001 2 1001 10 0010 3 1010 11 0011 4 1011 12 0100 5 1100 13 0101 6 1101 14 0110 7 1110 15 0111 8 1111 16 CFR2<7:6> Open Unused locations. Write a Logic 0. CFR2<5> CP Polarity This bit sets the polarity of the charge pump, in response to a ground referenced or a supply referenced VCO. CFR2<5> = 0 (default). The charge pump is configured to operate with a supply referenced VCO. If PLLOSC lags PLLREF, the charge pump will attempt to drive the VCO control node voltage higher. If PLLOSC leads PLLREF, the charge pump will attempt to drive the VCO control node voltage lower. CFR2<5> = 1. The charge pump is configured to operate with a ground referenced VCO. If PLLOSC lags PLLREF, the charge pump will attempt to drive the VCO control node voltage lower. If PLLOSC leads PLLREF, the charge pump will attempt to drive the VCO control node voltage higher. CFR2<4> Charge Pump Full Power-Down This bit, when set, will put the charge pump into a full power- down mode. CFR2<4> = 0 (default). The charge pump is powered on and operating normally. CFR2<4> = 1. The charge pump is completely powered down. CFR2<3> Charge Pump Quick Power-Down Rather than power down the charge pump, which can take a long time to recover from, a quick power-down mode, which powers down only the charge pump output buffer, is included. While this doesn’t reduce the power consumption significantly, it does shut off the output to the charge pump and allows it to come back on in a rapidly. CFR2<3> = 0 (default). The charge pump is powered on and operating normally. CFR2<3> = 1. The charge pump is on and running, but the output buffer is powered down. CFR2<2:0> Charge Pump Current Scale. A base output current from the charge pump is determined by a resistor connected from the CP_RSET pin to ground (see the PLL Circuitry section). However, it is possible to multiply the charge pump output current by a value from 1:8 by programming these bits. The charge pump output current are scaled by CFR2<2:0> +1. CFR2<2:0> = 000 (default). Scale factor = 1 to CFR2<2:0> = 111 (8). CFR2<2:0> Scale Factor 000 1 001 2 010 3 011 4 100 5 101 6 110 7 111 8 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |