302 / 456 page ![]() MEC1322 DS00001719D-page 302 2014 - 2015 Microchip Technology Inc. 26.9.6 FAN SPIN UP CONFIGURATION REGISTER The Fan Spin Up Configuration Register controls the settings of Spin Up Routine. TABLE 26-14: GAIN DECODE GAIND or GAINP or GAINI [1:0] Respective Gain Factor 10 00 1x 01 2x 1 0 4x (default) 11 8x Offset 06h Bits Description Type Default Reset Event 7:6 DRIVE_FAIL_CNT[1:0] Determines how many update cycles are used for the Drive Fail detection function as shown in Table 26-15, "DRIVE_FAIL_CNT[1:0] Bit Decode". This circuitry determines whether the fan can be driven to the desired Tach target. These settings only apply if the Fan Speed Control Algorithm is enabled. R/W 00b VCC1_R ESET 5NOKICK Determines if the Spin Up Routine will drive the fan to 100% duty cycle for 1/4 of the programmed spin up time before driving it at the programmed level. • ‘0’ (default) - The Spin Up Routine will drive the PWM to 100% for 1/4 of the programmed spin up time before reverting to the programmed spin level. • ‘1’ - The Spin Up Routine will not drive the PWM to 100%. It will set the drive at the programmed spin level for the entire duration of the programmed spin up time. R/W 0b VCC1_R ESET 4:2 SPIN_LVL[2:0] SPIN_LVL[2:0] - Determines the final drive level that is used by the Spin Up Routine as shown in Table 26-16, "Spin Level". R/W 110b VCC1_R ESET 1:0 SPINUP_TIME[1:0] Determines the maximum Spin Time that the Spin Up Routine will run for. If a valid tachometer measurement is not detected before the Spin Time has elapsed, an interrupt will be generated. When the RPM based Fan Control Algorithm is active, the fan driver will attempt to re-start the fan immediately after the end of the last spin up attempt. The Spin Time is set as shown in Table 26-17, "Spin time". R/W 01b VCC1_R ESET TABLE 26-15: DRIVE_FAIL_CNT[1:0] BIT DECODE DRIVE_FAIL_CNT[1:0] Number of Update Periods 10 0 0 Disabled - the Drive Fail detection circuitry is disabled 0 1 16 - the Drive Fail detection circuitry will count for 16 update periods |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |