22 / 33 page ![]() SM8213AM NIPPON PRECISION CIRCUITS—22 Bit 11 CLKO clock output enable flag. When 0, output is enabled. When 1, output is disabled. If CLKO clock output is not used, it can be useful in preventing unwanted noise generation. Bits 12 to 13 Receive bit rate set flags. Bit 14 NRZ input signal polarity select flag. When 0, normal logic is selected. When 1, inverse logic is selected. Bits 15 to 20 BS3 (PLL setup signal) setup time set flags. “M” represents the value of PL5 (MSB) to PL0 (LSB) and is used to control the receive timing setup time before BS3 rising edge. The setup time is 1.953M ms (0.833M ms) [0.417M ms]. The valid values are from 2 to 62 (61 steps). Note that 3FH is an invalid setting. Bits 21 to 26 BS1 (RF control main output signal) setup time set flags. “N” represents the value of RF5 (MSB) to RF0 (LSB) and is used to control the receive timing setup time before BS3 rising edge. The setup time is 1.953N ms (0.833N ms) [0.417N ms]. The valid val- ues are from 2 to 62 (61 steps). Note that 3EH and 3FH are invalid settings. Note also that the setup times should be set such that (BS3 rising-edge setup time) > (BS1 rising-edge setup time). Bit 27 NRZ signal input noise canceller filter ON/OFF flag. When 0, filter is OFF. When 1, filter is ON. Bits 28 to 29 These bits set the noise canceller filter on-state (strength) when the filter is turned ON using bit 27. Bits 30 to 32 Preamble mode rate error detection condition set flags. In preamble mode, under worst-case reception con- ditions, a single standard is used when distinguishing between noise and preamble to detect rate errors. These flags determine the rate error detection stan- dard. The error counter value (number of permissible rate errors) can be selected from the range 1 to 8. BRS1 BRS0 Reception bit rate 0 0 512 bps 0 1 1200 bps 1 0 2400 bps 1 1 Can't accept FILTER 1 FILTER 0 Filter strength1 1. Filter ON-state strength: 1 < 2 < 3 < 4 0 0 Filter strength 1 0 1 Filter strength 2 1 0 Filter strength 3 1 1 Filter strength 4 ER 2 ER 1 ER 0 Threshold 0 0 0 Count = 1 0 0 1 Count = 2 0 1 0 Count = 3 0 1 1 Count = 4 1 0 0 Count = 5 1 0 1 Count = 6 1 1 0 Count = 7 1 1 1 Count = 8 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |