20 / 55 page ![]() TMP007 SBOS685C – APRIL 2014 – REVISED JULY 2015 www.ti.com 7.3.8.9 Two-Wire Timing The TMP007 is two-wire and SMBus compatible. Figure 23 to Figure 26 describe the various operations on the TMP007. Parameters for Figure 23 are defined in Table 5. Bus definitions are: Bus Idle Both SDA and SCL lines remain high. Start Data Transfer A change in the state of the SDA line, from high to low, while the SCL line is high defines a start condition. Each data transfer is initiated with a start condition. Stop Data Transfer A change in the state of the SDA line from low to high while the SCL line is high defines a stop condition. Each data transfer is terminated with a repeated start or stop condition. Data Transfer The number of data bytes transferred between a start and a stop condition is not limited, and is determined by the master device. The receiver acknowledges the transfer of data. It is also possible to use the TMP75B for single-byte updates. To update only the MS byte, terminate communication by issuing a start or stop condition on the bus. Acknowledge Each receiving device, when addressed, must generate an acknowledge bit. A device that acknowledges must pull down the SDA line during the acknowledge clock pulse so that the SDA line is stable low during the high period of the acknowledge clock pulse. Setup and hold times must be taken into account. When a master receives data, the termination of the data transfer can be signaled by the master generating a not-acknowledge (1) on the last byte transmitted by the slave. Table 5. Two-Wire Timing Requirements FAST MODE HIGH-SPEED MODE UNIT MIN MAX MIN MAX f(SCL) SCL operating frequency 0.001 0.4 0.001 2.5 MHz t(BUF) Bus free time between stop and start condition 1300 260 ns t(HDSTA) Hold time after repeated start condition. 600 160 ns After this period, the first clock is generated. t(SUSTA) Repeated start condition setup time 600 160 ns t(SUSTO) Stop condition setup time 600 160 ns t(HDDAT) Data hold time 0 900 0 150 ns t(SUDAT) Data setup time 100 30 ns t(LOW) SCL clock low period 1300 260 ns t(HIGH) SCL clock high period 600 60 ns tF, tR – SDA Data fall and rise time 300 80 ns tF, tR – SCL Clock fall and rise time 300 40 ns tR Rise time for SCL ≤ 100 kHz 1000 ns 20 Submit Documentation Feedback Copyright © 2014–2015, Texas Instruments Incorporated Product Folder Links: TMP007 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |