15 / 55 page ![]() TMP007 www.ti.com SBOS685C – APRIL 2014 – REVISED JULY 2015 7.3.5 Calibration The TMP007 default coefficients are calibrated with a black body of emissivity, ε = 0.95, and an FOV (θ) = 110°. Use these coefficients for applications where the object emissivity and geometry satisfy these conditions. For applications with different object emissivity or geometry, calibrate the TMP007 to accurately reflect the object temperature and system geometry. Accuracy is affected by device-to-device or object-to-object variation. For the most demanding applications, calibrate each device individually. As an overview the calibration procedure includes: 1. Defining the environmental variation range (die and object temperature range, supply voltage, temperature change speed, sampling rate and so on). 2. Making the die temperature measurements and IR sensor voltage measurements over the environmental range. 3. Generate an optimal set of coefficients based on the collected data set. 4. Load the coefficients into the TMP007 coefficients register. The object temperature register reflects the best fit from the calibration process. Perform validation measurements because accuracy may vary over the environmental range. If the object temperature measurement error is not acceptable, repeat the calibration process using more environment points, data averaging, or narrow the temperature range of TDIE or TOBJ. 5. After a suitable set of coefficients is obtained, they can be stored in nonvolatile memory. Each coefficient register can be programmed up to eight times. After POR, the last stored coefficient value is copied from the nonvolatile memory into the coefficient register. The best temperature precision is available if every device is calibrated individually. Alternatively, if all the units in the application use the same coefficients, then calibrate a statistically significant number of devices, and load averaged coefficient values in nonvolatile memory. Recalibration may be required under any or all of the following conditions: 1. Board layout changed. 2. Object or objects in the field of view changed. 3. Object distance or object surface changed. 4. Angle between device surface and direction to the object changed. 5. Object and local temperature range changed outside the environmental calibration range. 6. Object and local temperature transients significantly changed. 7. Supply voltage changed more than 1 V. 8. Air convection or conduction near the device changed. For further information and methods for calibration, refer to SBOU142 — TMP007 Calibration Guide. Copyright © 2014–2015, Texas Instruments Incorporated Submit Documentation Feedback 15 Product Folder Links: TMP007 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |