33 / 83 page ![]() Start of Period Period Counter Start of Period Filter Period Adaptive Sample Trigger A Sample Trigger 1 DPWM Output A DTC Adjustment Filter Duty ± 2 x Event 1 Event 1 2 x Event 1 DTC Adjustment Event 1 DPWM Output B Blanking A Begin Blanking A End Blanking B Begin Blanking B End Phase Trigger Sample Trigger 2 To Other Modules To Other Modules x x Filter controlled edge x x x x xx xx x x x x Adaptive Sample Trigger B UCD3138A www.ti.com SLUSC66B – MARCH 2015 – REVISED MAY 2015 6.5.3 DPWM Resonant Mode This mode provides a symmetrical waveform where DPWMA and DPWMB have the same pulse width. As the switching frequency changes, the dead times between the pulses remain the same. The equations for this mode are designed for a smooth transition from PWM mode to resonant mode, as described in Section 6.7.2. The diagram of this mode is shown in Figure 6-3. The Filter has two outputs, Filter Duty and Filter Period. In this case, the Filter is configured so that the Filter Period is twice the Filter Duty. So if there were no dead times, each DPWM pin would be on for half of the period. For dead time handling, the average of the two dead times is subtracted from the Filter Duty for both DPWM pins. Therefore, both pins will have the same on-time, and the dead times will be fixed regardless of the period. The only edge which is fixed relative to the start of the period is the rising edge of DPWM A. This is the only edge for which the blanking signals can be used easily. Events which change with DPWM mode: • DPWM A Rising Edge = Event 1 • DPWM A Falling Edge = Filter Duty – Event 1 • Adaptive Sample Trigger A = Event 1 + Filter Duty + Adaptive Sample Register or • Adaptive Sample Trigger B = Event 1 + Filter Duty/2 + Adaptive Sample Register • DPWM B Rising Edge = Filter Duty + Event 1 • DPWM B Falling Edge = Filter Period – Event 1 • Phase Trigger = Phase Trigger Register value or Filter Duty Events always set by their registers, regardless of mode: • Sample Trigger 1, Sample Trigger 2, Blanking A Begin, Blanking A End, Blanking B • Begin, Blanking B End Figure 6-3. Resonant Symmetrical Closed Loop Copyright © 2015, Texas Instruments Incorporated Detailed Description 33 Submit Documentation Feedback Product Folder Links: UCD3138A |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |