73 / 80 page ![]() Data Sheet ADAS1000/ADAS1000-1/ADAS1000-2 Rev. A | Page 73 of 80 Example 4: Configure 150 Hz Test Tone Sine Wave on Each ECG Channel and Stream Conversion Data 1. Write 1 configures the CMREFCTL register to VCM_REF = 1.3 V (no electrodes contribute to VCM). RLD is enabled to RLD_OUT, and the shield amplifier enabled. 2. Write 2 addresses the TESTTONE register to enable the 150 Hz sine wave onto all electrode channels. 3. Write 3 addresses the FILTCTL register to change the internal low-pass filter to 250 Hz to ensure that the 150 Hz sine wave can pass through. 4. Write 4 configures the FRMCTL register to output nine words per frame/packet. The frame/packet of words consists of the header and five ECG words, pace, respiration magnitude, and lead-off. The frame is configured to always send, irrespective of ready status. The ADAS1000 is in electrode format mode with a data rate of 2 kHz. Electrode format is required to see the test tone signal correctly on each electrode channel. 5. Write 5 addresses the ECGCTL register, enabling all channels into a gain of 1.4, low noise mode. It configures the device as a master and driven from the XTAL input source. The ADAS1000 is also put into conversion mode in this write. 6. Write 6 issues the read command to start putting the converted data out on the SDO pin. 7. Continue to issue SCLK cycles to read the converted data at the configured packet data rate. Example 5: Enable Pace Detection and Stream Conversion Data 1. Write 1 configures the PACECTL register with all three pace detection instances enabled, PACE1EN detecting on Lead II, PACE2EN detecting on Lead I, and PACE3EN detecting on Lead aVF. The pace width filter and validation filters are also enabled. 2. Write 2 issues the read command to start putting the converted data out on the SDO pin. 3. Continue to issue SCLK cycles to read the converted data at the configured packet data rate. When a valid pace is detected, the detection flags are confirmed in the header word and the PACEDATA register contains information on the width and height of the measured pulse from each measured lead. 4. Note that the PACEAMPTH register default setting is 0x242424, setting the amplitude of each of the pace instances to 1.98 mV/gain. 5. Note that this example assumes that the FRMCTL register has already been configured such that the PACEDATA word is available in the data frame, as arranged in Write 2 of Example 1. Table 57. Example 4: Configure 150 Hz Test Tone Sine Wave on Each ECG Channel and Stream Conversion Data Write Command Register Addressed Read/Write Bit Register Address Data 32-Bit Write Command Write 1 CMREFCTL 1 000 0101 0000 0000 0000 0000 0000 1011 0x8500000B Write 2 TESTTONE 1 000 1000 1111 1000 0000 0000 0000 1101 0x88F8000D Write 3 FILTCTL 1 000 1011 0000 0000 0000 0000 0000 1000 0x8B000008 Write 4 FRMCTL 1 000 1010 0000 0111 1001 0110 0001 0000 0x8A079610 Write 5 ECGCTL 1 000 0001 1111 1000 0000 0000 1010 1110 0x81F800AE Write 6 FRAMES 0 100 0000 0000 0000 0000 0000 0000 0000 0x40000000 Table 58. Example 5: Enable Pace Detection and Stream Conversion Data Write Command Register Addressed Read/Write Bit Register Address Data 32-Bit Write Command Write 1 PACECTL 1 000 0100 0000 0000 0000 1111 1000 1111 0x84000F8F Write 2 FRAMES 0 100 0000 0000 0000 0000 0000 0000 0000 0x40000000 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |