| поискавой системы для электроныых деталей |
|
ADAS1000BSTZ датащи(PDF) 63 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADAS1000BSTZ датащи(HTML) 63 Page - Analog Devices |
|
63 / 80 page ![]() Data Sheet ADAS1000/ADAS1000-1/ADAS1000-2 Rev. A | Page 63 of 80 Table 35. Frame Control Register (FRMCTL) Address 0x0A, Reset Value = 0x079000 R/W Default Bit Name Function R/W 0 23 LEAD I/LADIS Include/exclude word from ECG data frame. If the electrode/lead is included in the data- word and the electrode falls off, the data-word is undefined. 0 (default) = included in frame. 1 = exclude from frame. R/W 0 22 LEADII/LLDIS R/W 0 21 LEADIII/RADIS R/W 0 20 V1DIS R/W 0 19 V2DIS R/W 1111 [18:15] Reserved Reserved, set to 1111. R/W 0 14 PACEDIS1 Pace detection. 0 (default) = included in frame. 1 = exclude from frame. R/W 0 13 RESPMDIS1 Respiration magnitude. 0 (default) = included in frame. 1 = exclude from frame. R/W 1 12 RESPPHDIS1 Respiration phase. 0 = included in frame. 1 (default) = exclude from frame. R/W 0 11 LOFFDIS Lead-off status. 0 (default) = included in frame. 1 = exclude from frame. R/W 0 10 GPIODIS GPIO word disable. 0 (default) = included in frame. 1 = exclude from frame. R/W 0 9 CRCDIS CRC word disable. 0 (default) = included in frame. 1 = exclude from frame. R/W 0 8 RESERVED Reserved, set to 0. R/W 0 7 ADIS Automatically excludes PACEDIS[14], RESPMDIS[13], LOFFDIS[11] words if their flags are not set in the header. 0 (default) = fixed frame format. 1 = autodisable words (words per frame changes). R/W 0 6 RDYRPT Ready repeat. If this bit is set and the frame header indicates data is not ready, the frame header is continuously sent until data is ready. 0 (default) = always send entire frame. 1 = repeat frame header until ready. R/W 0 5 Reserved Reserved, set to 0 . R/W 0 4 DATAFMT Sets the output data format, see Figure 57. 0 (default) = digital lead/vector format (available only in 2 kHz and 16 kHz data rates). 1 = electrode format. R/W 00 [3:2] SKIP[1:0] Skip interval. This field provides a way to decimate the data. 00 (default) = output every frame. 01 = output every other frame 1× = output every 4th frame. R/W 00 [1:0] FRMRATE[1:0] Sets the output data rate. 00 (default) = 2 kHz output data rate. 01 = 16 kHz output data rate. 10 = 128 kHz output data rate (DATAFMT must be set to 1). 11 = 31.25 Hz. 1 ADAS1000 model only, ADAS1000-1/ADAS1000-2 models do not contain these features. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |