39 / 80 page ![]() Data Sheet ADAS1000/ADAS1000-1/ADAS1000-2 Rev. A | Page 39 of 80 Figure 68. Respiration Using External Capacitor and External Amplifiers If required, further improvements in respiration performance may be possible with the use of an instrumentation amplifier and op amp external to the ADAS1000. The instrumentation amplifier must have sufficiently low noise performance to meet the target performance levels. This mode uses the external capacitor mode configuration and is shown in Figure 68. Bit 14 of the RESPCTL register (Table 28) allows the user to bypass the on-chip amplifier when using an external instrumentation amplifier. Respiration Carrier In applications where an external signal generator is used to develop a respiration carrier signal, that external signal source can be synchronized to the internal carrier using the signal available on GPIO3 when Bit 7, RESPEXTSEL, is enabled in the respiration control register (see Table 28). EVALUATING RESPIRATION PERFORMANCE ECG simulators offer a convenient means of studying the ADAS1000’s performance. While many simulators offer a variable-resistance respiration capability, care must be taken when using this feature. Some simulators use electrically programmable resistors, often referred to as digiPOTs, to create the time-varying resistance to be measured by the respiration function. The capacitances at the digitPOT's terminals are often unequal and code-dependent, and these unbalanced capacitances can give rise to unexpectedly large or small results on different leads for the same programmed resistance variation. Best results are obtained with a purpose- built fixture that carefully balances the capacitance presented to each ECG electrode. EXTEND SWITCH ON RESPIRATION PATHS There is additional multiplexing on the external respiration inputs to allow them to serve as additional electrode inputs to the existing five ECG ADC channels. This approach allows a user to configure eight electrode inputs; however, it is not intended as a true 8-channel/12-lead solution. Time overheads will be required to reconfigure the multiplexer arrangement using the serial interface in addition to filter the latency as described in Table 14. The user has full control over the SW1/SW2/SW3 configuration as outlined in Table 48. Figure 69. Alternative Use of the Respiration Paths LA CABLE ADAS1000 50kHz TO 56kHz 46.5kHz TO 64kHz OVERSAMPLED 1kΩ 10kΩ 10kΩ 10kΩ 10kΩ 1kΩ 100Ω 100Ω RESPDAC_LA RESPDAC_RA 1nF TO 10nF 1nF TO 10nF RESPIRATION DAC DRIVE + ve CABLE AND ELECTRODE IMPEDANCE < 1kΩ RA CABLE RESPIRATION MEASURE RESPIRATION DAC DRIVE – ve HPF IN-AMP AND ANTI-ALIASING MAGNITUDE AND PHASE SAR ADC EXT_RESP_LA EXT_RESP_RA REFOUT = 1.8V 0.9V GAIN 1/2 OF AD8606 1/2 OF AD8606 ±1V ±1V LPF TO ECG1_LA CHANNEL TO ECG2_LL CHANNEL TO ECG3_RA CHANNEL TO ECG4_V1 CHANNEL TO ECG5_V2 CHANNEL EXT_RESP_RA EXT_RESP_LL EXT_RESP_LA SW1a SW1b SW1c SW1d SW1e SW2a SW2b SW2c SW2d SW2e SW3a SW3b SW3c SW3d SW3e TO RESPIRATION CIRCUITRY |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |