36 / 52 page ![]() AD9974 Rev. A | Page 36 of 52 STANDBY MODE OPERATION The AD9974 contains two standby modes to optimize the overall power dissipation in a particular application. Bit 1 and Bit 0 of Address 0x00 control the power-down state of the device. STANDBY[1:0] = 00 = normal operation (full power) STANDBY[1:0] = 01 = reference standby mode STANDBY[1:0] = 10 or 11 = total shutdown mode (lowest power) Table 20 summarizes the operation of each power-down mode. The OUT_CONTROL register takes priority over the reference standby mode in determining the digital output states, but total shutdown mode takes priority over OUT_CONTROL. Total shutdown mode has the lowest power consumption. When returning from total shutdown mode to normal operation, the timing core must be reset at least 100 μs after the STANDBY register is written to. There is an additional register to disable the internal voltage reference buffer (Address 0x00[2]) independently. By default the buffer is disabled, but it must be enabled for normal operation. CLI FREQUENCY CHANGE If the input clock, CLI, is interrupted or changes to a different frequency, the timing core must be reset for proper operation. After the CLI clock has settled to the new frequency, or the previous frequency has resumed, write 0 and then 1 to the TGCORE_RST register (Address 0x14). This guarantees proper timing core operation. Table 20. Standby Mode Operation I/O Block Total Shutdown (Default)1, 2 OUT_CONTROL = Low2 Reference Standby AFE Off No change Only REFT, REFB on Timing Core Off No change On H1 High-Z Low Low (4.3 mA) H2 High-Z High High (4.3 mA) H3 High-Z Low Low (4.3 mA) H4 High-Z High High (4.3 mA) HL High-Z Low Low (4.3 mA) RG High-Z Low Low (4.3 mA) DOUT Low3 Low Low 1 To exit total shutdown, write 00 to STANDBY (Address 0x00, Bits[1:0]), then reset the timing core after 100 μs to guarantee proper settling. 2 Total shutdown mode takes priority over OUT_CONTROL for determining the output polarities. 3 The status of the DOUT pins is unknown at power-up. Low status is guaranteed in total shutdown mode after the power-up sequence is completed. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |