19 / 28 page ![]() ADM1024 –19– REV. 0 INTERRUPT STATUS MIRROR REGISTERS Whenever a bit in one of the Interrupt Status Registers is updated, the same bit is written to duplicate registers at addresses 4Ch and 42h. These registers allow a second management system to access the status data without worrying about clearing the data. The data in these registers is for reading only and has no effect on the interrupt output. TEMPERATURE INTERRUPT MODES The ADM1024 has two distinct methods of producing interrupts for out-of-limit temperature measurements from the internal or external sensors. Temperature errors can generate an interrupt on the INT pin along with other interrupts, but there is also a separate THERM pin that generates an interrupt only for temperature errors. Operation of the INT output for temperature interrupts is illustrated in Figure 22. Assuming that the temperature starts off within the programmed limits and that temperature interrupt sources are not masked, INT will go low if the temperature measured by any of the internal or external sensors exceeds the programmed high temperature limit for that sensor, or the hard- ware limits in register 13h, 14h, 17h, or 18h. 100 C 90 C 80 C 70 C 60 C 50 C 40 C TEMP HIGH LIMIT LOW LIMIT ACPI CONTROL METHODS CLEAR EVENT INT * * * * * * *ACPI AND DEFAULT CONTROL METHODS ADJUST TEMPERATURE LIMIT VALUES Figure 22. Operation of INT for Temperature Interrupts Once the interrupt has been cleared, it will not be reasserted even if the temperature remains above the high limit(s). However, INT will be reasserted if: a. the temperature falls below the low limit for the sensor or b. the high limit is/are reprogrammed to a new value, and the temperature then rises above the new high limit on the next monitoring cycle or c. the THERM pin is pulled low externally, which sets Bit 5 of Interrupt Status Register 2 or d. An interrupt is generated by another source. Similarly, should the temperature measured by a sensor start off within limits then fall below the low limit, INT will be asserted. Once cleared, it will not be reasserted unless: a. the temperature rises above the high limit or b. the low limit is/are reprogrammed, and the temperature then falls below the new low limit or c. the THERM pin is pulled low externally, which sets Bit 5 of Interrupt Status Register 2 or d. an interrupt is generated by another source. THERM INPUT/OUTPUT The Thermal Management Input/Output ( THERM) is a logic input/output with an internal, 100 k Ω pull-up resistor, that provides a separate output for temperature interrupts only. It is enabled by setting Bit 2 of Configuration Register 1. The THERM output has two operating modes that can be programmed by Bit 3 of Configuration Register 2 (address 4Ah). With this bit set to the default value of 0, the THERM output operates in “Default” interrupt mode. With this bit set to 1, the THERM output oper- ates in “ACPI” mode. Thermal interrupts can still be generated at the INT output while THERM is enabled, but if these are not required they can be masked by writing a 1 to bit 0 of Configuration Register 2 (address 4Ah). The THERM pin can also function as a logic input for an external sensor, for example a temperature sensor such as the ADM22105 used in Figure 23b. If THERM is taken low by an external source, the analog output will be forced to FFh to switch a controlled fan to maximum speed. This also generates an INT output as previously described. DEFAULT MODE In Default mode, the THERM output operates like a thermostat with hysteresis. THERM will go low and Bit 5 of Interrupt Status Register 2 will be set, if the temperature measured by any of the sensors exceeds the high limit programmed for that sensor. It will remain asserted until reset by reading Interrupt Status Register 2, by setting Bit 6 of Configuration Register 1, or when the temperature falls below the low limit programmed for that sensor. ANALOG OUTPUT FFH CLEARED BY TEMP FALLING BELOW LOW LIMIT TEMP HIGH LIMIT THERM TEMP PROGRAMMED VALUE EXT THERM INPUT CLEARED BY READ OR THERM CLEAR TEMP LOW LIMIT Figure 23a. INT or THERM Output in Default Mode |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |