16 / 28 page ![]() ADM1024 –16– REV. 0 If the fan has a strong pull-up (less than 1 k Ω) to 12 V, or a totem-pole output, then a series resistor can be added to limit the Zener current, as shown in Figure 17c. Alternatively, a resistive attenuator may be used, as shown in Figure 17d. R1 and R2 should be chosen such that: 2 V < VPULL-UP × R2/(R PULL-UP + R1 + R2) < 5 V The fan inputs have an input resistance of nominally 160 k Ω to ground, so this should be taken into account when calculating resistor values. With a pull-up voltage of 12 V and pull-up resistor less than 1 k Ω, suitable values for R1 and R2 would be 100 k Ω and 47 kΩ. This will give a high-input voltage of 3.83 V. 12V TACHO OUTPUT FAN1 OR FAN2 VCC FAN SPEED COUNTER ZD1* ZENER *CHOOSE ZD1 VOLTAGE APPROX. 0.8 VCC PULL-UP TYP. <1k OR TOTEM-POLE R1 10k 160k Figure 17c. Fan with Strong Tach. Pull-Up to >VCC or Totem-Pole Output, Clamped with Zener and Resistor 12V <1k TACHO OUTPUT FAN1 OR FAN2 VCC *SEE TEXT R2* R1* FAN SPEED COUNTER 160k Figure 17d. Fan with Strong Tach. Pull-Up to >VCC or Totem-Pole Output, Attenuated with R1/R2 FAN SPEED MEASUREMENT The fan counter does not count the fan tach output pulses directly, because the fan speed may be less than 1000 rpm and it would take several seconds to accumulate a reasonably large and accu- rate count. Instead, the period of the fan revolution is measured by gating an on-chip 22.5 kHz oscillator into the input of an 8-bit counter for two periods of the fan tach output, as shown in Fig- ure 18; the accumulated count is actually proportional to the fan tach period and inversely proportional to the fan speed. 22.5kHz CLOCK CONFIG. REG. 1 BIT 0 FAN1 INPUT FAN2 INPUT START OF MONITORING CYCLE FAN1 MEASUREMENT PERIOD FAN2 MEASUREMENT PERIOD Figure 18. Fan Speed Measurement The monitoring cycle begins when a one is written to the Start Bit (Bit 0), and a zero to the INT_Clear Bit (Bit 3) of the Configuration Register. INT_Enable (Bit 1) should be set to one to enable the INT output. The measurement begins on the rising edge of a fan tach pulse, and ends on the next-but-one rising edge. The fans are monitored sequentially, so if only one fan is monitored the monitoring time is the time taken after the Start Bit for it to produce two complete tach cycles or for the counter to reach full scale, whichever occurs sooner. If more than one fan is monitored, the monitoring time depends on the speed of the fans and the timing relationship of their tach pulses. This is illustrated in Figure 19. Once the fan speeds have been measured, they will be stored in the Fan Speed Value Registers and the most recent value can be read at any time. The measure- ments will be updated as long as the monitoring cycle continues. To accommodate fans of different speed and/or different num- bers of output pulses per revolution, a prescaler (divisor) of 1, 2, 4, or 8 may be added before the counter. The default value is 2, which gives a count of 153 for a fan running at 4400 rpm producing two output pulses per revolution. The count is calculated by the equation: Count = (22.5 × 103 × 60) /(rpm × Divisor) For constant speed fans, fan failure is normally considered to have occurred when the speed drops below 70% of nominal, which would correspond to a count of 219. Full scale (255) would be reached if the fan speed fell to 60% of its nominal value. For temperature-controlled variable speed fans the situation will be different. Table V shows the relationship between fan speed and time per revolution at 60%, 70%, and 100% of nominal rpm for fan speeds of 1100, 2200, 4400, and 8800 rpm, and the divisor that would be used for each of these fans, based on two tach pulses per revolution. Table V. Fan Speeds and Divisors Time Time Time per per per Nominal Rev 70% Rev (70%) 60% Rev (60%) Divisor rpm (ms) rpm (ms) rpm (ms) ÷1 8800 6.82 6160 9.74 5280 11.36 ÷2 4400 13.64 3080 19.48 2640 22.73 ÷4 2200 27.27 1540 38.96 1320 45.44 ÷8 1100 54.54 770 77.92 660 90.90 FAN1 and FAN2 Divisors are programmed into Bits 4 to 7 of the VID 0–3/Fan Divisor Register. LIMIT VALUES Fans in general will not overspeed if run from the correct voltage, so the failure condition of interest is underspeed due to electrical or mechanical failure. For this reason only, low-speed limits are programmed into the limit registers for the fans. It should be noted that, since fan period rather than speed is being measured, a fan failure interrupt will occur when the measurement exceeds the limit value. MONITORING CYCLE TIME The monitoring cycle time depends on the fan speed and number of tach output pulses per revolution. Two complete periods of the fan tach output (three rising edges) are required for each fan |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |