| поискавой системы для электроныых деталей |
|
UCD3138 датащи(PDF) 47 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
UCD3138 датащи(HTML) 47 Page - Texas Instruments |
|
47 / 68 page ![]() FAULT - CBC FAULT - AB FAULT -A DCOMP – 4X EXT GPIO – 4X ACOMP – 7X FAULT -B FAULT MODULE FAULT MODULE FAULT MODULE CYCLE BY CYCLE AB FLAG AB FLAG A FLAG B FLAG DISABLE PWM A AND B DISABLE PWM A AND B DISABLE PWM A ONLY DISABLE PWM B ONLY FAULT MUX ALL_FAULT_EN DPWM_EN DPWM CBC_FAULT_EN CBC_PWM_AB_EN FAULT MODULE DIG PCM ANALOG PCM Bit20 in DPWMCTRL0 Bit30 in DPWMFLTCTRL Bit 31 in DPWMFLTCTRL Bit0 in DPWMCTRL0 UCD3138 www.ti.com SLUSAP2 A – MARCH 2012 – REVISED MARCH 2012 4.14.2 Fault Multiplexer In order to allow a flexible way of mapping several fault triggering sources to all the DPWMs channels, the UCD3138 provides an extensive array of multiplexers that are united under the name Fault Mux module. The Fault Mux Module supports the following types of mapping between all the sources of fault and all different fault response mechanism inside each DPWM module. • Many fault sources mapped to a single fault response mechanism. For instance an analog comparator in charge of over voltage protection, a digital comparator in charge of over current protection and an external digital fault pin can be all mapped to a fault-A signal connected to a single FAULT MODULE and shut down DPWM1-A. • A single fault source can be mapped to many fault response mechanisms inside many DPWM modules. For instance an analog comparator in charge of over current protection can be mapped to DPWM-0 through DPWM-3 by way of several fault modules. • Many fault sources can be mapped to many fault modules inside many DPWM modules. The Fault Mux Module provides a multitude of fault protection functions within the UCD3138 high-speed loop (Front End Control, Filter, DPWM and Loop Mux modules). The Fault Mux Module allows highly configurable fault generation based on digital comparators, high-speed analog comparators and external fault pins. Each of the fault inputs to the DPWM modules can be configured to one or any combination of the fault events provided in the Fault Mux Module. Each one of the DPWM engines has four fault modules. The modules are called CBC fault module, AB fault module, A fault module and B fault module. Copyright © 2012, Texas Instruments Incorporated Functional Overview 47 Submit Documentation Feedback Product Folder Link(s): UCD3138 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |