TLE7269G датащи(PDF) 17 Page - Infineon Technologies AG

номер детали TLE7269G
подробное описание детали  Twin LIN Transceiver
PDF  34 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  INFINEON [Infineon Technologies AG]
домашняя страница  http://www.infineon.com
Logo INFINEON - Infineon Technologies AG

TLE7269G датащи(HTML) 17 Page - Infineon Technologies AG

Back Button TLE7269G Datasheet HTML 13Page - Infineon Technologies AG TLE7269G Datasheet HTML 14Page - Infineon Technologies AG TLE7269G Datasheet HTML 15Page - Infineon Technologies AG TLE7269G Datasheet HTML 16Page - Infineon Technologies AG TLE7269G Datasheet HTML 17Page - Infineon Technologies AG TLE7269G Datasheet HTML 18Page - Infineon Technologies AG TLE7269G Datasheet HTML 19Page - Infineon Technologies AG TLE7269G Datasheet HTML 20Page - Infineon Technologies AG TLE7269G Datasheet HTML 21Page - Infineon Technologies AG Next Button
Zoom Inzoom in Zoom Outzoom out
 17 / 34 page
background image
Data Sheet
17
Rev. 1.2, 2007-11-13
TLE7269G
Functional Description
In Stand-By mode the RxD1 pin signals the low power supply condition with a “High” signal. A logical “High” on
the EN pin changes the operation mode back to Normal Operation mode.
In case the supply voltage
V
S is dropping below the specified operation range (see Table 5), the TLE7269G
disables the output and receiver stages. This feature secures the communication on the LIN bus. If the power
supply
V
S reaches a higher level as the Under-Voltage level VS > VS,UV,BLK the TLE7269G continues with normal
operation. A mode change only applies if the power supply
V
S drops below the power on reset level (VS <
V
S,UV,PON).
If the power supply
V
IO drops below the Under-Voltage level VIO > VIO,UV the output and receiver stages will be
disabled as well. When
V
IO reaches a higher level as the Under-Voltage VIO > VIO,UV level the TLE7269G continues
with normal operation and data transmission.
4.11
TxD Time Out function
If the TxD1 or TxD2 signal is dominant for a time t > ttimeout the TxD time-out function deactivates the transmission
of the LIN signal to the bus and disables both, the output stage 1 and the output stage 2. This is realized to prevent
the bus from being blocked by a permanent “Low” signal on the TxD1 or TxD2 pin, caused by an error on the
external microcontroller (see Figure 12).
The transmission is released again, after a rising edge at TxD1 or TxD2 has been detected.
Figure 12
TxD Time-Out function
TxD1
ttorec
BUS1
TxD2
BUS2
ttimeout
Normal Communication
Normal Communication
TxD Time-Out due to
microcontroller error
Release after TxD
Time-out
Recovery of the
microcontroller error
ttorec
ttimeout
Normal Communication
Normal Communication
TxD Time-Out due to
microcontroller error
Release after TxD
Time-out
Recovery of the
microcontroller error
t
t
t
t



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com