| поискавой системы для электроныых деталей |
|
TLE6240GP датащи(PDF) 23 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE6240GP датащи(HTML) 23 Page - Infineon Technologies AG |
|
23 / 37 page ![]() Data Sheet 23 Rev.3.3, 2010-02-15 TLE6240GP Smart 16-Channel Low-Side Switch Control of the Device 6.1.4 Control- and Data Byte As mentioned above, the serial input information consist of a control byte and a data byte. Via the control byte, the specific mode of the device is programmable. Ten specific control words are recognized, having the following functions: Table 2 Commands Control words beside No. 1- 10 Not specified Control words are not executed (cause no function) and the shift register (SO Data) is reset after the CS signal (all ‘0’). Table 1 Control and Data Byte MSB LSB CCCC CCCC DDDD DDDD Control Byte Data Byte No. Control Byte Data Byte Function Channel 1 to 8 1 LLLL LLLL1) XXXX XXXX2) ‘Full Diagnosis’ (two bits per channel) performed for channels 1 to 8. No change to output states. 2 HHLL LLLL XXXX XXXX State of the eight parallel inputs and ‘1-bit Diagnosis’ for channel 1 to 8 is provided. 3 HLHL LLLL XXXX XXXX Echo-function of SPI; SI direct connected to SO. 4 LLHH LLLL DDDDDDDD2) IN1 … 4 and serial data bits ‘OR’ed. ‘Full Diagnosis’ performed for channels 1 to 8. 5 HHHH LLLL DDDDDDDD IN1 … 4 and serial data bits ‘AND’ed. ‘Full Diagnosis’ performed for channels 1 to 8. Channel 9 to 16 6 LLLL HHHH1) XXXX XXXX ‘Full Diagnosis’ (two bits per channel) performed for channels 9 to 16. No change to output states. 7 HHLL HHHH XXXX XXXX State of the eight parallel inputs and ‘1-bit Diagnosis’ for channel 9 to 16 is provided. 8 HLHL HHHH XXXX XXXX Echo-function of SPI; SI direct connected to SO. 9 LLHH HHHH DDDDDDDD IN9 … 12 and serial data bits ‘OR’ed. ‘Full Diagnosis’ performed for channels 9 to 16. 10 HHHH HHHH DDDDDDDD IN9 … 12 and serial data bits ‘AND’ed. ‘Full Diagnosis’ performed for channels 9 to 16. 1) Control Byte: Channel Selection via Bit 0 to 3 Bits 0 to 3 = L, Channels 1 to 8 selected Bits 0 to 3 = H, Channels 9 to 16 selected 2) Data Byte: ‘X’ means ‘don’t care’, because this data bits will be ignored. ‘D’ represents the data bits, either being H (= ON) or L (= OFF). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |