| поискавой системы для электроныых деталей |
|
S5000PAL датащи(PDF) 65 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
S5000PAL датащи(HTML) 65 Page - Intel Corporation |
|
65 / 112 page ![]() Light Guided Diagnostics Intel ® Server Board S5000PAL / S5000XAL TPS Revision 1.7 Intel order number: D31979-010 66 The bi-color System Status LED will operate as follows: Color State Criticality Description Off N/A Not ready AC power off Green / Amber Alternating Blink Not ready Pre DC Power On – 15-20 second BMC Initialization when AC is applied to the server. Control Panel buttons are disabled until BMC initialization is complete. Green Solid on System OK System booted and ready. Green Blink Degraded System degraded • Unable to use all of the installed memory (more than one DIMM installed). • Correctable errors over a threshold of 10 and migrating to a spare DIMM (memory sparing). This indicates that the user no longer has spared DIMMs indicating a redundancy lost condition. Corresponding DIMM LED should light up. • In mirrored configuration, when memory mirroring takes place and system loses memory redundancy. This is not covered by (2). • Redundancy loss such as power-supply or fan. This does not apply to non-redundant sub-systems. • PCI-e link errors • CPU failure / disabled – if there are two processors and one of them fails • Fan alarm – Fan failure. Number of operational fans should be more than minimum number needed to cool the system • Non-critical threshold crossed – Temperature and voltage • Chassis Intrusion events, including lost LAN connection Amber Blink Non-critical Non-fatal alarm – system is likely to fail • Critical voltage threshold crossed • VRD hot asserted • Minimum number of fans to cool the system not present or failed • In non-sparing and non-mirroring mode if the threshold of ten correctable errors is crossed within the window Amber Solid on Critical, non- recoverable Fatal alarm – system has failed or shutdown • DIMM failure when there is one DIMM present, no good memory present • Run-time memory uncorrectable error in non-redundant mode • IERR signal asserted • Processor 1 missing • Temperature (CPU ThermTrip, memory TempHi, critical threshold crossed) • No power good – power fault • Processor configuration error (for instance, processor stepping mismatch) 7.2.1 System Status LED – BMC Initialization When the AC power is first applied to the system and 5V-STBY is present, the BMC controller on the server board requires 15-20 seconds to initialize. During this time, the system status LED will blink, alternating between amber and green, and the power button functionality of the control panel is disabled preventing the server from powering up. Once BMC initialization has completed, the status LED will stop blinking and the power button functionality is restored and can be used to turn on the server. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |