42 / 66 page ![]() MCP4017/18/19 DS22147A-page 42 © 2009 Microchip Technology Inc. Step resistance (RS) is the resistance from one tap setting to the next. This value will be dependent on the RAB value that has been selected. Equation 6-1 shows the calculation for the step resistance while Table 6-2 shows the typical step resistances for each device. EQUATION 6-1: RS CALCULATION Equation 6-2 illustrates the calculation used to determine the resistance between the wiper and terminal B. EQUATION 6-2: RWB CALCULATION The digital potentiometer is available in four nominal resistances (RAB) where the nominal resistance is defined as the resistance between terminal A and terminal B. The four nominal resistances are 5 k Ω, 10 k Ω, 50 kΩ, and 100 kΩ. The total resistance of the device has minimal variation due to operating voltage (see Figure 2-11, Figure 2-29, Figure 2-47, or Figure 2-65). TABLE 6-2: STEP RESISTANCES A POR/BOR event will load the Volatile Wiper register value with the default value. Table 6-3 shows the default values offered. TABLE 6-3: DEFAULT FACTORY SETTINGS SELECTION Part Number Resistance ( Ω) Case Total (RAB) Step (RS) MCP4017/18/19-502E Min. 4000 31.496 Typical 5000 39.370 Max. 6000 47.244 MCP4017/18/19-103E Min. 8000 62.992 Typical 10000 78.740 Max. 12000 94.488 MCP4017/18/19-503E Min. 40000 314.961 Typical 50000 393.701 Max. 60000 472.441 MCP4017/18/19-104E Min. 80000 629.921 Typical 100000 787.402 Max. 120000 944.882 RS RAB 127 --------- = RWB RABN 127 -------------- RW + = N = 0 to 127 (decimal) Resistance Code Typical RAB Value Default POR Wiper Setting Code (1) -502 5.0 k Ω Mid-scale 3Fh -103 10.0 k Ω Mid-scale 3Fh -503 50.0 k Ω Mid-scale 3Fh -104 100.0 k Ω Mid-scale 3Fh Note 1: Custom POR/BOR Wiper Setting options are available, contact the local Microchip Sales Office for additional information. Custom options have minimum volume requirements. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |