| поискавой системы для электроныых деталей |
|
TSC2008RGVR датащи(PDF) 14 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TSC2008RGVR датащи(HTML) 14 Page - Texas Instruments |
|
14 / 37 page ![]() INTERNAL TEMPERATURE SENSOR Converter GND V DD +IN - IN GND REF DV + kT q @ ln(N) (3) T + q @ DV k @ ln(N) (4) TSC2008 SBAS406A – JUNE 2008 – REVISED DECEMBER 2008 .................................................................................................................................................. www.ti.com In some applications, such as battery recharging, an ambient temperature measurement is required. The temperature measurement technique used in the TSC2008 relies on the characteristics of a semiconductor junction operating at a fixed current level. The forward diode voltage (VBE) has a well-defined characteristic versus temperature. The ambient temperature can be predicted in applications by knowing the +25°C value of the VBE voltage and then monitoring the delta of that voltage as the temperature changes. The TSC2008 offers two modes of temperature measurement. The first mode requires calibration at a known temperature, but only requires a single reading to predict the ambient temperature. The TEMP1 diode, shown in Figure 23, is used during this measurement cycle. This voltage is typically 580mV at +25°C with a 10 µA current. The absolute value of this diode voltage can vary by a few millivolts; the temperature coefficient (TC) of this voltage is very consistent at –2.1mV/°C. During the final test of the end product, the diode voltage is stored at a known room temperature, in system memory, for calibration purposes by the user. The result is an equivalent temperature measurement resolution of 0.3°C/LSB (1LSB = 610 µV with V REF = 2.5V). Figure 23. Functional Block Diagram of Temperature Measurement Mode The second mode does not require a test temperature calibration, but uses a two-measurement (differential) method to eliminate the need for absolute temperature calibration and for achieving 2°C/LSB accuracy. This mode requires a second conversion of the voltage across the TEMP2 diode with a resistance 91 times larger than the TEMP1 diode. The voltage difference between the first (TEMP1) and second (TEMP2) conversion is represented by: Where: N = the resistance ratio = 91. k = Boltzmann's constant = 1.3807 × 10–23 J/K (joules/kelvins). q = the electron charge = 1.6022 × 10–19 C (coulombs). T = the temperature in kelvins (K). This method can provide much improved absolute temperature measurement, but a lower resolution of 1.6°C/LSB. The resulting equation to solve for T is: Where: ΔV = VBE (TEMP2) – VBE(TEMP1) (in mV). ∴ T = 2.573 ⋅ ΔV (in K), or T = 2.573 ⋅ ΔV – 273 (in °C). Temperature 1 and/or temperature 2 measurements have the same timing as shown in Figure 30 to Figure 33. 14 Submit Documentation Feedback Copyright © 2008, Texas Instruments Incorporated Product Folder Link(s): TSC2008 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |