42 / 56 page ![]() Clock operation M41T93 42/56 DocID12615 Rev 8 3.15 Initial power-on defaults Upon initial application of power to the device, the register bits will initially power-on in the state indicated in Table 13 and Table 14. Table 13. Initial power-on default values (part 1) Table 14. Initial power-up default values (part 2) 3.16 OTP bit operation (SOX18 package only) Using the factory-supplied analog calibration value When the OTP (one time programmable) bit is set to a 1, the factory calibration value in the internal OTP register will be transferred to the analog calibration register (12h) and is “read only.” The OTP value is programmed by the manufacturer, and will contain the value necessary to achieve typically ±5 ppm(a) (VCC only) at room temperature after two SMT reflows. This clock accuracy can be guaranteed to drift no more than ±3 ppm the first year, and ±1 ppm for each following year due to crystal aging. If the OTP bit is set to 0, the analog calibration register will become a WRITE/READ register and function like an ordinary register, allowing the user to implement any desired value of analog calibration. When the user sets the OTP bit, they need to wait for approximately 8 ms before the analog registers transfer the value from the OTP to the analog registers due to the OTP read operation. Condition(1) 1. All other control bits power-up in an undetermined state ST CB1 CB0 OUT FT DCS ACS Digital calib. Analog calib. OFIE Watchdog(2) 2. BMB0-BMB4, RB0, RB1 A1IE SQWE ABE Initial power-up 00 0 1 0 0 0 0 0 0 0 1 0 Subsequent power-up(3)(4) 3. With battery backup 4. UC = Unchanged UC UC UC UC 0 UC UC UC UC 0 UC UC UC Condition(1) 1. All other control bits power-up in an undetermined state RPT11-15 HT OF TE TI/TP TIE TD1 TD0 RS0 RS1-3 OTP RPT21-25 AL2E Initial power-up 01 1 0 0 0 1 1 1 0 0 0 0 Subsequent power-up (2)(3) 2. With battery backup 3. UC = Unchanged UC 1 UC 0 UC UC UC UC UC UC UC UC UC a. Max. value = +12 ppm / –5 pmm based on limited data |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |