| поискавой системы для электроныых деталей |
|
ACT5101 датащи(PDF) 44 Page - Qorvo, Inc |
|
|
|||||||||||||||||||||||||||||
ACT5101 датащи(HTML) 44 Page - Qorvo, Inc |
|
44 / 59 page ![]() Data Sheet Rev. E, November 2019 | Subject to change without notice 44 of 59 www.qorvo.com © 2020 Qorvo US, Inc. All rights reserved. ACT510x 23V Buck-Boost Converter with Integrated MOSFETs REG 0x06: Faults 2 (Read only) (VM) Bit Name Default Value Description Comment 7 WATCHDOG_FAULT 0 0: No Fault 1: Watchdog Fault Watchdog Timeout Fault This bit is latching. If Watchdog is enabled and watchdog timer times out, then this bit is set high. This bit is not cleared when read. The watchdog timer is cleared with a watchdog read or by disabling the watchdog timer. 6 VOUT_FAULT 0 0: No Fault 1: VOUT Fault Output Hiccup Mode Fault This bit is latching. Read this bit to clear the value back to 0. If the VOUT enters hiccup state because current exceeds the Constant Current Mode, then this bit gets set. This register will always be set during hiccup mode when VOUT is off during the 3sec restart time and converter is in the HICCUP state. After it exits this state, a read clears this bit. 5 VIN_UV_FLT 0 0: No Fault 1: VIN UV Fault VIN UV Fault This bit is latching. If VIN falls below the VIN_UV_OFFSET Voltage specified in the VIN_UV_OFFSET Register (Reg 0x0F, Bits 7:5), this bit is set to 1. When the input voltage is above the VIN_UV_OFFSET voltage, a read will clear this fault bit. 4 VOUT_OV 0 0: No Fault 1: VOUT OV Fault Vout Overvoltage Fault Read to Clear latching bit This bit will be set any time the Vout exceeds the OV threshold for external or internal feedback. The VOUT must be below the OV voltage and then a read will clear this fault bit. 3 LIGHT_LOAD 0 0: No Fault 1: Converter off Output Light Load State Latch This bit is latching. This bit is set when the converter has been disabled because of light load condition on output and it entered the LL_DIS state. After the IC exits the LL_DIS state, a read clears this bit. 2 VIN_OV 0 0: No Fault 1: VIN OV VIN Overvoltage fault This bit is latching. This bit is set any time VIN exceeds the OV threshold when in the POWER ON state. VIN must be below the OV voltage and then a read clears this bit. 1 I2C_FAULT 0 0: No Fault 1: I2C Fault If set to 1, I2C command did not finish correctly or errors on I2C data 0 RFU 0 Reserved for future use. Do not change. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |