| поискавой системы для электроныых деталей |
|
ELANSC310 датащи(PDF) 50 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
ELANSC310 датащи(HTML) 50 Page - Advanced Micro Devices |
|
50 / 119 page ![]() 50 Élan™SC310 Microcontroller Data Sheet PREL IMINARY PGP Pins PGP2 and PGP3 can be programmed to be set to a pre-defined state for Micro Power Off mode. For more information, see the ÉlanTMSC310 Microcontroller Pro- grammer’s Reference Manual, order # 20665. Micro Power Off Mode Implementation The system should not be powered up directly into Micro Power Off mode. The system must be allowed to fully power up into High Speed mode upon initial power application of any power source. If a battery has insuf- ficient power for the ÉlanSC310 microcontroller to ini- tialize into High Speed mode, the system design must first power up the ÉlanSC310 microcontroller from the main source, and not allow the chip to be powered from the battery until after it is fully initialized in High Speed mode and properly transitioned into Micro Power Off mode. This requirement presents an issue when using (for ex- ample) a 3 V Lithium battery cell as a back-up power source to prevent the RTC from losing its contents dur- ing Micro Power Off mode. If the battery is installed be- fo re any othe r power sour ce is available, the requirement cannot be met because such a small bat- tery is incapable of supplying sufficient power to fully initialize the system. The ÉlanSC310 microcontroller comes up in an undefined state, perhaps drawing suf- ficient current to drain the battery. The ÉlanSC310 microcontroller backup power source should be installed only after the system is powered by the main power source prior to a transition into Micro Power Off mode. When the system has transitioned into Micro Power Off mode properly, the simultaneous benefits of low power consumption while maintaining RTC data such as time, date, and system configuration can be realized. Note: The timing sequence and specifications for power-up, entering, and exiting Micro Power Off mode must be met. The timing information begins on page 88. For more information about Micro Power Off mode im- plementation, see the ÉlanTMSC300 and ÉlanTMSC310 Microcontrollers Solution For Systems Using a Back- up Battery Application Note , order #20746 and the Troubleshooting Guide for Micro Power Off Mode on ÉlanTMSC300 and ÉlanSC310 Microcontrollers and Evaluation Boards Application Note , order #21810. Core Peripheral Controllers The ÉlanSC310 microcontroller includes all the stan- dard peripheral controllers that make up a PC/AT sys- tem, including interrupt controller, DMA controller, counter/timer, and ISA bus controller. For more infor- mation, see Chapter 3 of the ÉlanTMSC310 Microcon- troller Programmer’s Reference Manual, order #20665. Interrupt Controller The ÉlanSC310 microcontroller interrupt controller is functionally compatible with the standard cascaded 8259A controller pair as implemented in the PC/AT. The interrupt controller block accepts requests from peripherals, resolves priority on pending interrupts and interrupts in service, issues an interrupt request to the processor, and provides the interrupt vector to the processor. The two devices are internally connected and must be programmed to operate in Cascade mode for operation of all 15 interrupt channels. Interrupt controller 1 occu- pies I/O addresses 020h–021h and is configured for master operation in Cascade mode. Interrupt controller 2 occupies I/O addresses 0A0h–0A1h and is config- ured for slave operation. Channel 2 (IRQ2) of interrupt controller 1 is used for cascading and is not available externally. The output of Timer 0 in the counter/timer section is connected to Channel 0 (IRQ0) of Interrupt controller 1. IRQ0 can be programmed to generate an SMI. See Chapter 1 of the ÉlanTMSC310 Microcontroller Pro- grammer’s Reference Manual, order #20665. Interrupt request from the Real-Time Clock is connected to Channel 0 (IRQ8) of Interrupt Controller 2. IRQ13 is re- Table 23. Internal I/O Pulldown States IORESET RESIN Force Term Comments 0 0 Active This condition occurs when any power source is initially turned on. The ÉlanSC310 microcontroller’s core and analog VCC is transitioning to on and RESIN is active (the initial power-up state). See “Micro Power Off Mode” on page 46 for more details. 0 1 Active This condition occurs when the core and analog VCC is stable, the RESIN pin has been inactive, and the primary power supply outputs are off (the normal Micro Power Off state). 1 0 Active This condition should be treated as condition 0,0 above. 1 1 Inactive This occurs when the secondary power supply is on, the RESIN input is inactive, and the primary power supply is on and has deasserted IORESET (normal system operating state). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |