34 / 110 page ![]() DSP56366 Technical Data, Rev. 3.1 3-8 Freescale Semiconductor 27 Interrupt Requests Rate • HDI08, ESAI, ESAI_1, SHI, DAX, Timer •DMA •IRQ, NMI (edge trigger) •IRQ (level trigger) 12TC 8TC 8TC 12TC — — — — 100.0 66.7 66.7 100.0 ns ns ns ns 28 DMA Requests Rate • Data read from HDI08, ESAI, ESAI_1, SHI, DAX • Data write to HDI08, ESAI, ESAI_1, SHI, DAX •Timer •IRQ, NMI (edge trigger) 6TC 7TC 2TC 3TC — — — 50.0 58.0 16.7 25.0 ns ns ns 29 Delay from IRQA, IRQB, IRQC, IRQD, NMI assertion to external memory (DMA source) access address out valid 4.25 × T C + 2.0 37.4 — ns 1 V CC = 3.3 V ± 0.16 V; TJ = –40°C to + 110°C, CL = 50 pF 2 Periodically sampled and not 100% tested. 3 RESET duration is measured during the time in which RESET is asserted, V CC is valid, and the EXTAL input is active and valid. When the VCC is valid, but the other “required RESET duration” conditions (as specified above) have not been yet met, the device circuitry will be in an uninitialized state that can result in significant power consumption and heat-up. Designs should minimize this state to the shortest possible duration. 4 If PLL does not lose lock. 5 When using fast interrupts and IRQA, IRQB, IRQC, and IRQD are defined as level-sensitive, timings 19 through 21 apply to prevent multiple interrupt service. To avoid these timing restrictions, the deasserted Edge-triggered mode is recommended when using fast interrupts. Long interrupts are recommended when using Level-sensitive mode. 6 WS = number of wait states (measured in clock cycles, number of T C). Use expression to compute maximum value. 7 This timing depends on several settings: For PLL disable, using external clock (PCTL Bit 16 = 1), no stabilization delay is required and recovery time will be defined by the PCTL Bit 17 and OMR Bit 6 settings. For PLL enable, if PCTL Bit 17 is 0, the PLL is shutdown during Stop. Recovering from Stop requires the PLL to get locked. The PLL lock procedure duration, PLL Lock Cycles (PLC), may be in the range of 0 to 1000 cycles. This procedure occurs in parallel with the stop delay counter, and stop recovery will end when the last of these two events occurs: the stop delay counter completes count or PLL lock procedure completion. PLC value for PLL disable is 0. The maximum value for ETC is 4096 (maximum MF) divided by the desired internal frequency (i.e., for 120 MHz it is 4096/120 MHz = 34.1 μs). During the stabilization period, T C, TH, and TL will not be constant, and their width may vary, so timing may vary as well. Table 3-7 Reset, Stop, Mode Select, and Interrupt Timing1 (continued) No. Characteristics Expression Min Max Unit |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |