25 / 39 page ![]() When the voltage on POTP drops below VPOVTH the conversion is stopped and the device enters fault. The fault is managed as conditioned-restart. 8.7.7 Primary side undervoltage lockout In case the voltage on PVCC drops below VPVCCOff the IC enters auto-restart fault mode. 8.7.8 Fault summary The following table summarizes the faults and their effect. Table 10. Faults table Fault Side Effect Comment UVLO Primary Auto-restart OVP Primary Enter burst Primary side stops and enters burst. In case the secondary side gives no signal, the system enters UVLO. OCP Primary Auto-restart Second level OC may happen in case of output short. The effect is a shutdown. SSTO Primary Auto-restart Soft-start timeout (SS pin reached VSSEND). POTP Primary Conditioned-restart Overtemperature protection. BO Primary Conditioned-restart In case of brown-out, switching is stopped. Primary side stops until the BO condition disappears. All fault conditions are cleared. XCD Primary Conditioned-restart X-Cap discharge is managed in the same way as brown-out. OCP Secondary Load switch Turn off If load switch is not present, protection is performed by primary side OCP. OVP Secondary Enter burst If OVP is triggered secondary side stops and waits the voltage drop under safe condition. UVP Secondary Auto-restart If UVP last for 480us the system stops switching waiting for primary side restart. UVLO Secondary Auto-restart If secondary side hits UVLO, the system stops switching waiting for primary side restart. SOTP Secondary Auto-restart The secondary overtemperature value is programmable and is considered also a warning temperature (if enabled) before the SOTP. The fault does not stop switching, but turns off the load switch and sends a hard reset command on the USB-PD. 8.8 X-cap discharge Safety regulations such as IEC 62368-1 require that the capacitors directly connected to the input plug (so called “X-Caps”) are discharged when the converter mains connector is removed from the outlet, in order to avoid the risk of electrical shock to the user. Typically, this function is performed by means of a resistor in parallel, but this method cannot be applied in case the converter requires very low power consumption during light-load or no-load operation, because the losses of the X-cap discharging resistor would be too high. The ST-ONEMP monitors the input voltage through the HV pin and discharges the X-capacitors through the HV pin TXCDDET after a plug disconnection is detected. The discharge continues until the voltage on HV falls below VHVmin or the plug is connected again. Note that a DC voltage on the HV pin is interpreted as a plug disconnection, so the device cannot operate with DC input voltage. ST-ONEMP X-cap discharge DS13989 - Rev 2 page 25/39 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |