| поискавой системы для электроныых деталей |
|
LSM6DSV16X датащи(PDF) 95 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
LSM6DSV16X датащи(HTML) 95 Page - STMicroelectronics |
|
95 / 196 page ![]() 9.60 TAP_DUR (5Ah) Tap recognition function setting register (R/W) Table 163. TAP_DUR register DUR_3 DUR_2 DUR_1 DUR_0 QUIET_1 QUIET_0 SHOCK_1 SHOCK_0 Table 164. TAP_DUR register description DUR_[3:0] Duration of maximum time gap for double-tap recognition. Default: 0000 When double-tap recognition is enabled, this register expresses the maximum time between two consecutive detected taps to determine a double-tap event. The default value of these bits is 0000b which corresponds to 16/ODR_XL time. If the DUR_[3:0] bits are set to a different value, 1LSB corresponds to 32/ODR_XL time. QUIET_[1:0] Expected quiet time after a tap detection. Default value: 00 Quiet time is the time after the first detected tap in which there must not be any overthreshold event. The default value of these bits is 00b which corresponds to 2/ODR_XL time. If the QUIET_[1:0] bits are set to a different value, 1LSB corresponds to 4/ODR_XL time. SHOCK_[1:0] Maximum duration of overthreshold event. Default value: 00 Maximum duration is the maximum time of an overthreshold signal detection to be recognized as a tap event. The default value of these bits is 00b which corresponds to 4/ODR_XL time. If the SHOCK_[1:0] bits are set to a different value, 1LSB corresponds to 8/ODR_XL time. 9.61 WAKE_UP_THS (5Bh) Single/double-tap selection and wake-up configuration (R/W) Table 165. WAKE_UP_THS register SINGLE_ DOUBLE_TAP USR_OFF _ON_WU WK_THS_5 WK_THS_4 WK_THS_3 WK_THS_2 WK_THS_1 WK_THS_0 Table 166. WAKE_UP_THS register description SINGLE_DOUBLE_TAP Enables single/double-tap event. Default value: 0 (0: only single-tap event enabled; 1: both single and double-tap events enabled) USR_OFF_ON_WU Drives the low-pass filtered data with user offset correction (instead of high-pass filtered data) to the wake-up and the activity/inactivity functions. Refer to Figure 32. Default value: 0 WK_THS_[5:0] Wake-up threshold. The resolution of the threshold depends on the value of WU_INACT_THS_W_[2:0] in the INACTIVITY_DUR (54h) register. Default value: 000000 LSM6DSV16X TAP_DUR (5Ah) DS13510 - Rev 1 page 95/196 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |