| поискавой системы для электроныых деталей |
|
STM32WL55JC датащи(PDF) 123 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STM32WL55JC датащи(HTML) 123 Page - STMicroelectronics |
|
123 / 147 page ![]() DS13293 Rev 2 123/147 STM32WL55/54xx Electrical characteristics 137 Figure 23. Typical connection diagram when using the ADC with FT/TT pins featuring analog switch function 1. Refer to Table 82: ADC accuracy for the values of RAIN, RADC and CADC. 2. Cparasitic represents the capacitance of the PCB (dependent on soldering and PCB layout quality) plus the pad capacitance (refer to Table 75: I/O static characteristics for the value of the pad capacitance). A high Cparasitic value downgrades the conversion accuracy. To remedy this, fADC must be reduced. 3. Refer to Table 75: I/O static characteristics for the values of Ilkg. 4. Refer to Section 3.10.1: Power supply schemes. General PCB design guidelines Power supply decoupling must be performed as shown in Figure 13: Power supply scheme. The 100 nF capacitor must be ceramic (good quality) and must be placed as close as possible to the chip. 5.3.20 Temperature sensor characteristics MSv67871V3 Sample-and-hold ADC converter Converter Cparasitic (2) Ilkg (3) CADC VDDA (4) RAIN (1) VAIN RADC VREF+ (4) VSSA I/O analog switch Sampling switch with multiplexing VSS VSS Table 83. TS characteristics Symbol Parameter Min Typ Max Unit TL(1) VTS linearity with temperature - ±1 ±2 °C Avg_Slope(2) Average slope 2.3 2.5 2.7 mV/°C V30 Voltage at 30 °C (±5 °C)(3) 0.742 0.76 0.785 V tSTART (TS_BUF)(1) Sensor buffer startup time in continuous mode(4) -8 15 µs tSTART(1) Startup time when entering in continuous mode(4) -70 120 µs tS_temp(1) ADC sampling time when reading the temperature 5 - - µs IDD(TS)(1) Temperature sensor consumption from VDD, when selected by the ADC -4.7 7 µA 1. Guaranteed by design. 2. Guaranteed by characterization results. 3. Measured at VDDA = 3.3 V ±10 mV. The V30 ADC conversion result is stored in the TS_CAL1 byte. Refer to Table 12: Temperature sensor calibration values. 4. Continuous mode means Run and Sleep modes, or temperature sensor enable in LPRun and LPSleep modes. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |