22 / 60 page ![]() 7.2 Inverse current behavior Inverse current (VOUTn_S > VOUTn_D) in high-side configuration may occur with channels in ON or in OFF state. A reverse current applied to a specific channel has no impact on the general functionality (switch ON and OFF, protection, diagnostic) of unaffected channels. Parameter deviations are possible for the switching capability of the affected channel, while protection against Over Load and off state diagnostic are not available. Reliability in Limp Home condition for the unaffected channels remains unchanged. 7.3 Bulb inrush mode Although device is optimized for relays and LED, it may be necessary to use one or more of the outputs as high-side switches to drive small lamps or electronic loads with a big input capacitor. In such a case the inrush current mat startup may trigger the overload diagnostic, switching the channel OFF. In normal operation in order to re-engage the channels from an overload condition, an SPI command to clear the latches (register DIAG_OVC_OVT) is needed, to allow the channel turning ON again; for some applications this re-engagement procedure takes too long to transfer enough energy to activate the load. The IC provides means to overcome this issue by setting BIM.OUTn bit to “1”. Once this feature is enabled, in case the channel reaches the overload current threshold and latches OFF, it restarts automatically after a time tINRUSH, allowing the load to go out of the inrush phase. The automatic re-engagement of the faulty channels lasts for a BIM time (tBIM). Once the tBIM counter is started, it is reset only once the tBIM is expired, unless a reset condition occurs (VDDIO_uv, hardware or software reset). A time diagram is shown in Figure 11. The channel configured with BIM option can be either driven by an SPI command, PWM command (internal generator) or INn parallel input. Once programmed to “1” via SPI, the BIM.OUTn bit is set back to “0” at the end of BIM time (tBIM), unless a reset condition occurs (VDDIO_uv, hardware or software reset): an eventual switch off of the channel commanded by the user has no impact on BIM.OUTn configuration. Figure 11. Bulb inrush mode When BIM.OUTn are set to “1”, eventual overcurrent/overtemperature conditions will flag DIAG_OVC_OVT.OUTn bit, but the affected channels will not be permanently switched OFF. Once asserted, eventual SPI attempt to clear DIAG_OVC_OVT.OUTn will be ignored, until the BIM counter is expired. In order to resume the normal behavior when the BIM counter is expired, the DIAG_OVC_OVT.OUTn shall be cleared in order to allow IC to perform open load ON diagnosis. An internal timer set the bit BIM.OUTn back to “0” after 40 ms (parameter tBIM) starting from the first overcurrent event latched to prevent an excessive thermal stress to the channel, especially in case of short circuit at the output. L9026 Inverse current behavior DS13397 - Rev 5 page 22/60 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |