43 / 131 page ![]() The host should periodically update CBTIMER to ensure that it does not count down to zero. If the countdown timer is allowed to reach zero, the cell-balancing switches are disabled until the timer is either disabled or refreshed by writing a nonzero value. To allow timed balancing with no host interaction, the GPIO3 pin is configured to output a logic-high level while the timer is counting using the GPIO3TMR configuration bit of the GPIO register. An external diode is connected from GPIO3 to SHDNL to prevent shutdown while the timer is counting. Once the timer expires, the device shuts down. The host may intervene prior to the timer expiring to keep the device active and to reconfigure the device. Emergency-Discharge Mode The emergency-discharge mode performs cell-balancing in a controlled manner so the cells can be discharged to a safe level in the event of an emergency. The BALSWDCHG and DEVCFG1 registers provide control for this mode. A timeout value for the mode is configured by DISCHGTIME[7:0], as shown in Table 15. The emergency-discharge mode is activated by setting the EMGCYDCHG bit with DCHGTIME[7:0] ≠ 00h. In emergency-discharge mode, the following occurs: 1) The CBTIMER[3:0] is cleared to prevent the cell- balancing watchdog from disabling the cell balancing. 2) Cell-balancing switches are controlled by BALSWDCHG, not BALSWEN. 3) The discharge timer starts to count down. 4) Read-only counter DCHGCNTR[3:0] increments at a 2Hz rate with periodic rollover at Fh. The host can read this counter periodically to confirm the mode is active. 5) The GPIO3 pin is driven high while the countdown is active. The emergency-discharge mode alternates between a 1-minute discharge cycle for odd cells and a 1-minute discharge cycle for even cells. There is a 62.5ms minimum off-time at the end of each discharge cycle to ensure no overlap between even and odd discharge cycles. The duty cycle of each discharge cycle can be configured by DCHGWIN[2:0], as shown in Table 15. By clearing EMGCYDCHG, the emergency-discharge mode terminates and the following occurs: 1) The discharge timer is reset. 2) Control of the cell-balancing switches reverts to the BALSWEN register. 3) Control of GPIO3 reverts to the GPIO register. The emergency-discharge mode also terminates if DCHGTIME[7:0] = 0h or the discharge time has reached the configured timeout. To prevent the emergency-discharge mode from terminat- ing prematurely due to a device shutdown (which could occur due to an extended lapse in host communications), connect an external diode from GPIO3 to SHDNL to keep SHDNL high while the timer is counting. Table 15. Emergency Discharge Mode FUNCTION REGISTER FIELD CONFIGURATION BEHAVIOR Duty cycle DCHGWIN[2:0] 7.5s/bit 0h Switches on for 7.5s, off for 52.5s 1h Switches on for 15s, off for 45s … … 7h Switches on for 59.94s, off for 62.5ms Timeout DCHGTIME[7:0] 2 hours/bit 00h Discharge mode disabled 01h Discharge mode disabled after 4 hours 02h Discharge mode disabled after 6 hours … … FFh Discharge mode disabled after 512 hours MAX17843 12-Channel, High-Voltage Smart Sensor Data-Acquisition Interface www.maximintegrated.com Maxim Integrated │ 43 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |