| поискавой системы для электроныых деталей |
|
MAX17843ACB датащи(PDF) 28 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX17843ACB датащи(HTML) 28 Page - Maxim Integrated Products |
|
28 / 131 page ![]() Once the signal is properly conditioned, the ADC can start the conversion. The 12-bit conversion is stored in an ALU register where it can be averaged with subsequent con- versions. The ALU output is a 14-bit value and is ultimately stored in a 16-bit register with the two least-significant bits zero. Disabled channels result in a measurement value of 0000h. Unless stated otherwise, measurement values are assumed to be 14-bit values. The 16-bit register values can be converted to 14-bit values by dividing by 4 (and vice versa). To convert the measurement value in register CELLn to a voltage, convert the 14-bit hexadecimal value to a decimal value and then convert to voltage as follows: VCELLn = CELLn[15:2] x 5V/16384 = CELLn[15:2] x 305.176μV. Input Range The input range in unipolar mode is nominally 0 to 5V; however, the ADC has reduced linearity at its range extents and so accuracy is specified for the input range 0.2V to 4.8V. Some applications may require specified accuracy below 0.2V, or even below 0V. To this end, the bipolar mode (POLARITY = 1) has a nominal input range of -2.5V to +2.5V, as shown in Table 4, with accuracy specified from -2.3V to +2.3V. The input range can effectively be extended from -2.5V to +5V by taking one bipolar measurement and one unipo- lar measurement. Any bipolar measurements over 2.3V should be replaced with the unipolar measurement. Note: Conversions for some diagnostic modes automati- cally use either bipolar or unipolar mode, regardless of the POLARITY bit value. Block Voltage Input The VBLKP input (total module voltage) is selected for measurement by MEASUREEN14. The measurement is stored in the VBLOCK register with a full-scale value of 60V (3.662mV/bit). It can be compared to the sum of the cell voltages as a diagnostic. To precondition VBLKP for conversion, it is voltage-divided by a factor of 26. The divider is disconnected by default to minimize power consumption. The divider is connected by setting MEASUREEN15 (BLKCONNECT = 1) with sufficient set- tling time prior to the acquisition. For high acquisition rates, BLKCONNECT can remain enabled to reduce cycle time. Table 4. Input Range Figure 7. VBLKP Measurement CELL INPUT VOLTAGE CELLN[15:2] (14 BITS) CELLN[15:0] (16 BITS) BIPOLAR MODE (V) UNIPOLAR MODE (V) HEXADECIMAL DECIMAL -2.5 0 0000h 0d 0000h 0 2.5 2000h 8192d 8000h +2.5 5 3FFFh 16383d FFFCh + LV MUX ADC VREF VTHRM VBLKP AGND R2 = 384.5kΩ R1 = 10MΩ – R2 VBLKP/26 - MAX17843 12-Channel, High-Voltage Smart Sensor Data-Acquisition Interface www.maximintegrated.com Maxim Integrated │ 28 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |