79 / 131 page ![]() Cn Open Diagnostic If the cell is disconnected from the input, the correspond- ing cell-test source (sinking to AGND) pulls the cell input voltage toward 0V (except for C0, where source to VAA current source will pull the cell input voltage to VAA). A new measurement is taken with the current sources enabled, and a change in measurement value is detected. If no open circuit exists, then the measurement value changes by only the value of the test current across the application circuit series resistor to the Cn pin (see Table 44). Cn Shorted to SWn Diagnostic Short circuits between the SWn pins and the cell input pins are detectable. A shorted SWn pin can be detected by an acquisition with the relevant cell-balancing switch off and then again with it on. If the SWn pin is not shorted to an adjacent cell input pin, no change in the measured value should be observed for the two cases. If the SWn pin is shorted to the Cn pin, then the measured value will change by approximately 40% to 50% when the balancing switch is turned on based on the values of RBALANCE, and the balancing switch resistance. A short circuit from SWn to Cn-1 produces the same effect. By comparing both the VCELLn measurement value along with the VCELLn+1 and VCELLn-1 values, it is possible to deter- mine exactly where the short circuit is located. Note: I = Test source current, R = HVMUX resistance. Table 44. Cn Pin Open Diagnostic Cn PIN OPEN FAULT LOCATION C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 Cell1 Cell1- 3.3V 0V NC NC NC NC NC NC NC NC NC NC NC Cell2 NC Cell2+ Cell1 0V NC NC NC NC NC NC NC NC NC NC Cell3 NC NC Cell3+ Cell2 0V NC NC NC NC NC NC NC NC NC Cell4 NC NC NC Cell4+ Cell3 0V NC NC NC NC NC NC NC NC Cell5 NC NC NC NC Cell5+ Cell4 0V NC NC NC NC NC NC NC Cell6 NC NC NC NC NC Cell6+ Cell5 0V NC NC NC NC NC NC Cell7 NC NC NC NC NC NC Cell7+ Cell6 0V NC NC NC NC NC Cell8 NC NC NC NC NC NC NC Cell8+ Cell7 0V NC NC NC NC Cell9 NC NC NC NC NC NC NC NC Cell9+ Cell8 0V NC NC NC Cell10 NC NC NC NC NC NC NC NC NC Cell10+ Cell9 0V NC NC Cell11 NC NC NC NC NC NC NC NC NC NC Cell11+ Cell10 0V NC Cell12 NC NC NC NC NC NC NC NC NC NC NC Cell12+ Cell11 0V MAX17843 12-Channel, High-Voltage Smart Sensor Data-Acquisition Interface www.maximintegrated.com Maxim Integrated │ 79 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |