Back Button MAX17843ACB Datasheet HTML 18Page - Maxim Integrated Products MAX17843ACB Datasheet HTML 19Page - Maxim Integrated Products MAX17843ACB Datasheet HTML 20Page - Maxim Integrated Products MAX17843ACB Datasheet HTML 21Page - Maxim Integrated Products MAX17843ACB Datasheet HTML 22Page - Maxim Integrated Products MAX17843ACB Datasheet HTML 23Page - Maxim Integrated Products MAX17843ACB Datasheet HTML 24Page - Maxim Integrated Products MAX17843ACB Datasheet HTML 25Page - Maxim Integrated Products MAX17843ACB Datasheet HTML 26Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 131 page
background image
PIN
NAME
TYPE
FUNCTION
1, 18, 19,
26, 27, 60
N.C.
Not Connected. Connect to ground or leave unconnected.
2, 4, 31
AGND
Ground
Analog Ground. Connect to negative terminal of cell 1 and ground plane.
3
SHDNL
Input
Active-Low Shutdown Input. Drive > 1.8V to enable operation and drive < 0.6V to reset
device and place in shutdown mode. +72V tolerant. If not driven externally, this input can
be controlled solely through UART communication and software control. Bypass with a
1nF capacitor to AGND. For single-ended UART, SHDNL must be driven externally.
5
VAA
Power
3.3V Regulator Output Used to Supply VDDL1, VDDL2, andVDDL3. Bypass with a 1µF
capacitor to ground.
6
TXUN
Output
Negative Output for Upper-Port Transmitter. Driven between VDDL3 and GNDL3.
7
TXUP
Output
Positive Output for Upper-Port Transmitter. Driven between VDDL3 and GNDL3.
8
GNDL1
Ground
Digital Ground. Connect to ground plane.
9
VDDL1
Power
3.3V Digital Supply. Connect externally to VAA and bypass with 0.47µF capacitor to
GNDL1.
10
GNDL3
Ground
Ground for Upper-Port Transmitter. Connect to ground plane.
11
VDDL3
Power
3.3V Supply for Upper-Port Transmitter. Connect externally to VAA and bypass with
0.47µF capacitor to GNDL3.
12
RXUN
Input
Negative Input for Upper-Port Receiver. Tolerates ±30V.
13
RXUP
Input
Positive Input for Upper-Port Receiver. Tolerates ±30V. Connect to ground for single-
ended operation.
14
GPIO3
I/O
General-Purpose I/O 3. Driven between VDDL1 and GNDL1. 2MΩ internal pulldown.
15
GPIO2
I/O
General-Purpose I/O 2. Driven between VDDL1 and GNDL1. 2MΩ internal pulldown.
16
GPIO1
I/O
General-Purpose I/O 1. Driven between VDDL1 and GNDL1. 2MΩ internal pulldown.
17
GPIO0
I/O
General-Purpose I/O 0. Driven between VDDL1 and GNDL1. 2MΩ internal pulldown.
20
TXLP
Output
Positive Output for Lower-Port Transmitter. Driven between VDDL2 and GNDL2.
21
TXLN
Output
Negative Output for Lower-Port Transmitter. Driven between VDDL2 and GNDL2.
22
VDDL2
Power
3.3V Supply for Lower-Port Transmitter. Connect externally to VAA and bypass with
0.47µF capacitor to GNDL2.
23
GNDL2
Ground
Ground for Lower-Port Transmitter. Connect to ground plane.
24
RXLP
Input
Positive Input for Lower-Port Receiver. Tolerates ±30V. Connect to ground for single-
ended operation.
25
RXLN
Input
Negative Input for Lower-Port Receiver. Tolerates ±30V.
28
CTG
Input
Reserved for Factory use. Connect to ground.
29
AUXIN2
Input
Auxiliary Voltage Input 2 to Measure External Temperature. Connect to a voltage-divider
consisting of a 10kΩ pullup to THRM and 10kΩ NTC thermistor to ground. If not used,
connect to the pullup only.
30
AUXIN1
Input
Auxiliary Voltage Input 1 to Measure External Temperature. Connect to a voltage-divider
consisting of a 10kΩ pullup to THRM and a 10kΩ NTC thermistor to ground. If not used,
connect to the pullup only.
32
THRM
Power
3.3V Switched Output. Used to supply the voltage-dividers for the auxiliary inputs. The
output is enabled only during measurements, or as configured by THRMMODE[1:0].
This output can source up to 2mA.
MAX17843
12-Channel, High-Voltage Smart Sensor
Data-Acquisition Interface
www.maximintegrated.com
Maxim Integrated │ 22
Pin Description



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com