| поискавой системы для электроныых деталей |
|
MAX17843ACB датащи(PDF) 69 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX17843ACB датащи(HTML) 69 Page - Maxim Integrated Products |
|
69 / 131 page ![]() Full-Scale ADC Diagnostic Measurement Stuck ADC output bits can be verified with a combination of the zero-scale and full-scale diagnostics. The zero- scale ADC diagnostic measurement (DIAGSEL[2:0] = 0b101) verifies that the ADC conversion results in FFFh when its input is at VAA in bipolar mode (since for an input ≥ 2.5V, DIAG[15:0] = FFF0h). For this measurement, the ADC is automatically set to bipolar mode. BALSW Diagnostics Four balancing switch diagnostic modes are available to facilitate the following diagnostics: ● Balancing switch shorted (BALSWDIAG[2:0] = 0b001) ● Balancing switch open (BALSWDIAG[2:0] = 0b010) ● Odd sense wire open (BALSWDIAG[2:0] = 0b101) ● Even sense wire open (BALSWDIAG[2:0] = 0b110) Enabling any of these modes automatically preconfigures the acquisition (e.g. enables the ALTMUX measurement path). The host must initiate the acquisition but the diag- nostic mode automatically compares the measurements to the specific thresholds, and sets any corresponding alerts. The host presets the thresholds as determined by the minimum and maximum resistance of the switch (RSW) specified in the Electrical Characteristics table and the intended cell-balancing current. During any balancing switch diagnostic mode, ALRTOV, ALRTUV and ALRTMSMTCH comparisons are dis- abled. After BALSWDIAG[2:0] is cleared, the modified configurations automatically return to their prior setting. The same configurations and comparisons could be implement- ed manually but at the expense of more host operations. BALSW Short Diagnostic A short-circuit fault in the balancing path could be a short between SWn and SWn-1 (see Figure 42), or that the balancing FET is stuck in the conducting state. In the short circuit state, the voltage between SWn and SWn-1 (switch voltage) is less than the voltage between Cn and Cn-1 (cell voltage). When enabled, the balancing switch short diagnostic mode (BALSWDIAG[2:0] = 0b001) functions as follows: ● Disables the balancing switches automatically ● Configures the acquisition using ALTMUX path auto- matically ● Host initiates the acquisition ● Compares the measurement to the threshold value BALSHRTTHR automatically ● If outside the threshold, sets the corresponding flag in ALRTBALSW automatically For the best sensitivity to leakage current, set the threshold value based on the minimum cell voltage minus a small noise margin (100mV), then update the threshold value periodically or every time a measurement is taken, depend- ing on how fast the cell voltages are expected to change. Figure 41. ADC Full-Scale Diagnostic ADC IN - ADC IN + LV MUX ADC REF THRM AGND VAA AGND ADC AUTOMATICALLY IN BIPOLAR MODE MAX17843 12-Channel, High-Voltage Smart Sensor Data-Acquisition Interface www.maximintegrated.com Maxim Integrated │ 69 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |