| поискавой системы для электроныых деталей |
|
AD9914/PCBZ датащи(PDF) 26 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9914/PCBZ датащи(HTML) 26 Page - Analog Devices |
|
26 / 45 page ![]() AD9914 Data Sheet Rev. F | Page 26 of 45 Event 13—An input/output update registers that the autoclear digital ramp accumulator bit is set, resetting the ramp accumulator. However, with an automatic clear, the ramp accumulator is held in reset for only a single DDS clock cycle. This forces the DRG output to the lower limit, but the ramp accumulator is immedi- ately made available for normal operation. In this example, the DRCTL pin remains Logic 1; therefore, the DRG output restarts the previous positive ramp profile. No-Dwell Ramp Generation The two no-dwell high and no-dwell low bits (0x01[18:17]) in CFR2 add to the flexibility of the DRG capabilities. During normal ramp generation, when the DRG output reaches the programmed upper or lower limit, it simply remains at the limit until the operating parameters dictate otherwise. However, during no-dwell operation, the DRG output does not necessarily remain at the limit. For example, if the digital ramp no-dwell high bit is set when the DRG reaches the upper limit, it automatically (and immediately) snaps to the lower limit (that is, it does not ramp back to the lower limit; it jumps to the lower limit). Likewise, when the digital ramp no-dwell low bit is set, and the DRG reaches the lower limit, it automatically (and immediately) snaps to the upper limit. During no-dwell operation, the DRCTL pin is monitored for state transitions only; that is, the static logic level is immaterial. During no-dwell high operation, a positive transition of the DRCTL pin initiates a positive slope ramp, which continues uninterrupted (regardless of any further activity on the DRCTL pin) until the upper limit is reached. During no-dwell low operation, a negative transition of the DRCTL pin initiates a negative slope ramp, which continues uninterrupted (regardless of any further activity on the DRCTL pin) until the lower limit is reached. Setting both no-dwell bits invokes a continuous ramping mode of operation; that is, the DRG output automatically oscillates between the two limits using the programmed slope parameters. Furthermore, the function of the DRCTL pin is slightly different. Instead of controlling the initiation of the ramp sequence, it only serves to change the direction of the ramp; that is, if the DRG output is in the midst of a positive slope and the DRCTL pin transitions from Logic 1 to Logic 0, the DRG immediately switches to the negative slope parameters and resumes oscilla- tion between the limits. Likewise, if the DRG output is in the midst of a negative slope and the DRCTL pin transitions from Logic 0 to Logic 1, the DRG immediately switches to the positive slope parameters and resumes oscillation between the limits. When both no-dwell bits are set, the DROVER signal produces a positive pulse (two cycles of the DDS clock) each time the DRG output reaches either of the programmed limits (assuming that the DRG over output enable bit (0x01[13]) is set). A no-dwell high DRG output waveform is shown in Figure 39. The waveform diagram assumes that the digital ramp no-dwell high bit is set and has been registered by an input/output update. The status of the DROVER pin is also shown with the assumption that the DRG over output enable bit has been set. The circled numbers in Figure 39 indicate specific events, which are explained as follows: Event 1—Indicates the instant that an input/output update registers that the digital ramp enable bit is set. Event 2—DRCTL transitions to Logic 1, initiating a positive slope at the DRG output. Event 3—DRCTL transitions to Logic 0, which has no effect on the DRG output. Event 4—Because the digital ramp no-dwell high bit is set, the moment that the DRG output reaches the upper limit, it imme- diately switches to the lower limit, where it remains until the next Logic 0 to Logic 1 transition of DRCTL. Event 5—DRCTL transitions from Logic 0 to Logic 1, which restarts a positive slope ramp. Event 6 and Event 7—DRCTL transitions are ignored until the DRG output reaches the programmed upper limit. Event 8—Because the digital ramp no-dwell high bit is set, the moment that the DRG output reaches the upper limit, it immedi- ately switches to the lower limit, where it remains until the next Logic 0 to Logic 1 transition of DRCTL. Operation with the digital ramp no-dwell low bit set (instead of the digital ramp no-dwell high bit) is similar, except that the DRG output ramps in the negative direction on a Logic 1 to Logic 0 transition of DRCTL and jumps to the upper limit upon reaching the lower limit. UPPER LIMIT P DDS CLOCK CYCLES 1 2 3 4 5 6 7 8 DRG OUTPUT LOWER LIMIT DRCTL POSITIVE STEP SIZE DROVER + t Figure 39. No-Dwell High Ramp Generation |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |