24 / 50 page ![]() TLE5012B Specification Data Sheet 24 Rev. 2.0, 2014-02 4.3.4 Angle Performance After internal calculation, the sensor has a remaining error, as shown in Table 4-9. The error value refers to BZ= 0mT and the operating conditions given in Table 4-2 “Operating range and parameters” on Page 19. The overall angle error represents the relative angle error. This error describes the deviation from the reference line after zero-angle definition. It is valid for a static magnetic field. If the magnetic field is rotating during the measurement, an additional propagation error is caused by the angle delay time (see Table 4-10 “Signal processing” on Page 27), which the sensor needs to calculate the angle from the raw sine and cosine values from the MR bridges. In fast-turning applications, prediction can be enabled to reduce this propagation error. If autocalibration (see Chapter 4.3.5) is enabled and the temperature changes by more than 5 Kelvin during 1.5 revolutions an additional error has to be added to the specified angle error in Table 4-9. This error depends on the temperature change (Delta Temperature) as well as from the initial temperature (Tstart) as shown in Figure 4-3. Once the temperature stabilizes and the application completes 1.5 revolutions, then the angle error is as specified in Table 4-9. For negative Delta Temperature changes (from higher to lower temperatures) the additional angle error will be smaller than the corresponding positive Delta Temperature changes (from lower to higher temperatures) shown in Figure 4-3. The Figure 4-3 applies to the worst case. Table 4-9 Angle performance Parameter Symbol Values Unit Note / Test Condition Min. Typ. Max. Overall angle error (with auto- calibration) αErr 0.61) 1) At 25°C, B = 30mT 1.0 ° Including lifetime and temperature drift2)3)4). Note: in case of temperature changes above 5 Kelvin within 1.5 revolutions refer to Figure 4-3 for additional angle error. 2) Including hysteresis error, caused by revolution direction change 3) Relative error after zero angle definition 4) Not subject to production test - verified by design/characterization Overall angle error (without auto- calibration) αErr 0.61) 1.3 ° Including temperature drift2)3)5) 5) 0h 1.9 ° Including lifetime and temperature drift2)3)4) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |