| поискавой системы для электроныых деталей |
|
TMP112BIDRLR датащи(PDF) 20 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMP112BIDRLR датащи(HTML) 20 Page - Texas Instruments |
|
20 / 32 page ![]() Measured Temperature T HIGH T LOW SN1511004 ALERT PIN (Comparator Mode) POL = 0 SN1511004 ALERT PIN (Interrupt Mode) POL = 0 SN1511004 ALERT PIN (Comparator Mode) POL = 1 SN1511004 ALERT PIN (Interrupt Mode) POL = 1 Read Read Time Read 20 TMP112 SBOS473F – MARCH 2009 – REVISED FEBRUARY 2018 www.ti.com Product Folder Links: TMP112 Submit Documentation Feedback Copyright © 2009–2018, Texas Instruments Incorporated Figure 16. Output Transfer Function Diagrams 7.5.3.4 Fault Queue (F1/F0) A fault condition exists when the measured temperature exceeds the user-defined limits set in the THIGH and TLOW registers. Additionally, the number of fault conditions required to generate an alert may be programmed using the fault queue. The fault queue is provided to prevent a false alert as a result of environmental noise. The fault queue requires consecutive fault measurements in order to trigger the alert function. Table 11 lists the number of measured faults that may be programmed to trigger an alert condition in the device. For THIGH and TLOW register format and byte order, see the High- and Low-Limit Registers section. Table 11. TMP112 family Fault Settings F1 F0 CONSECUTIVE FAULTS 0 0 1 0 1 2 1 0 4 1 1 6 7.5.3.5 Converter Resolution (R1 and R0) The converter resolution bits, R1 and R0, are read-only bits. The TMP112 family converter resolution is set on start up to 11 which sets the temperature register to a 12-bit resolution. 7.5.3.6 One-Shot (OS) When the device is in shutdown mode, writing a 1 to the OS bit begins a single temperature conversion. During the conversion, the OS bit reads 0. The device returns to the SHUTDOWN state at the completion of the single conversion. For more information on the one-shot conversion mode, see the One-Shot/Conversion Ready Mode (OS) section. 7.5.3.7 Extended Mode (EM) The extended mode bit configures the device for normal mode operation (EM = 0) or extended mode operation (EM = 1). In normal mode, the temperature register and the high and low limit registers use a 12-bit data format. For more information on the extended mode, see the Extended Mode (EM) section. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |