60 / 142 page ![]() DA9021/22 System PMIC with high efficiency USB power manager Datasheet Revision 2.5 17-Feb-2017 CFR0011-120-00 Rev 5 60 of 142 © 2017 Dialog Semiconductor Table 36: Wakeup events Signal / Condition Wakeup User event System event IRQ Charger attach: E_VBUS_DET X X X Charger removal: E_VBUS_REM X X X VDDOUT low prewarning: E_VDD_LOW X X X RTC alarm: E_ALARM X X X Sequencing finished: E_SEQ_RDY X X Voltage comparator: E_COMP_1V2 X X X Pressed On key: E_nONKEY X X X End of battery charging: E_CHG_END X X X Battery temperature: E_TBAT X X Manual ADC result ready: E_ADC_EOM X X GPIOs: E_GPIx X X X ADC 4, 5, threshold: via GPI01 X X X SYS_EN, PWR_EN, PWR1_EN (passive to active transition): via GPIO8, 9, 10 X X X HS-2-wire interface: via GPIO14 X X X 13.6.3 Power supply sequencer The start-up of DA9021/22 supplies is performed with a sequencer that contains a programmable step timer, a variable ID array of time slot pointers and four predefined pointers (SYSTEM_END, POWER_END, MAX_COUNT and PART_DOWN). The sequencer is able to control up to 14 IDs (3 buck converters, 5 LDOs, 4 feedback pin level controls, a Wait ID (GPI10) and a POWERDOWN register), which can be grouped in three power domains. The power domains have configurable size and their borders are described by the location pointers SYSTEM_END, POWER_END and MAX_COUNT. The lowest level power domain SYSTEM starts at step one and ends at the step that is described by the location pointer SYSTEM_END. The second level domain POWER starts at the successive step and ends at POWER_END. The third level domain POWER1 starts at the consecutive step and ends at MAX_COUNT. The values of pointers SYSTEM_END, POWER_END and MAX_COUNT are predefined in OTP registers and should be configured to be SYSTEM_END < POWER_END < MAX_COUNT. The domain SYSTEM by can be understood as a basic set of supplies that are mandatory to maintain the application in (at least) a standby/hibernate mode. If enabled via control OTPREAD_EN all supplies of DA9021/22 and the sequencer timer (registers R14 and R43 to R61) are configured with the default value from OTP before powering up the domain SYSTEM. This will cause a reconfiguration of all supplies that have been powered down with a preset voltage level. The second level domain POWER includes additional supplies required to power the main application and to set DA9021/22 in to ACTIVE mode. POWER1 can be understood as a subdomain of POWER that can be used for additional hardware/software initiated control of supply blocks during ACTIVE mode (for example for a sub- application like WLAN or GSM baseband). Supplies in domain POWER and POWER1 can be voltage pre-configured and by that sequentially changed during powering down, but will not be reset to their default values from OTP unless there is a power-up from domain SYSTEM. NOTE Running applications should be configured to ACTIVE mode (domain POWER is up) and pointer POWER_END has to be at least one time slot higher than SYSTEM_END. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |