| поискавой системы для электроныых деталей |
|
ADATE320 датащи(PDF) 20 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADATE320 датащи(HTML) 20 Page - Analog Devices |
|
20 / 83 page ![]() Data Sheet ADATE320 Rev. B | Page 19 of 82 VREF, VREFGND, AND DUTGND REFERENCE INPUT PINS SPECIFICATIONS Table 10. Parameter Min Typ Max Unit Test Level Test Conditions/Comments DC SPECIFICATIONS VREF Input Voltage Range 2.475 2.500 2.525 V D Provided externally, VREF = 2.500 V, VREFGND = 0.000 V VREF Input Bias Current 10 µA P Tested with 2.500 V applied DUTGND Input Voltage Range, Referenced to AGND −0.1 +0.1 V D DUTGND Input Bias Current −10 +10 µA P Tested at −100 mV and +100 mV TEMPERATURE MONITOR SPECIFICATIONS Table 11. Parameter Min Typ Max Unit Test Level Test Conditions/Comments DC SPECIFICATIONS Temperature Sensor Gain 10 mV/K D 3.00 V at room temperature, 300 K (23°C) Temperature Sensor Accuracy ±10 °C CT 20°C < TC < 80°C, VCCTHERM only (TJ = TC) ALARM FUNCTIONS SPECIFICATIONS Table 12. Parameter Min Typ Max Unit Test Level Test Conditions/Comments DC SPECIFICATIONS Overvoltage Alarm High, OVDH Functional Voltage Range −1.0 +5.0 V D OVDL DAC set to DAC Code 0x0000 (−2.5 V) Uncalibrated Error at −1.0 V −300 +200 mV P Includes 5% uncalibrated gain ±250 mV offset Uncalibrated Error at 5.0 V 0 500 mV P Includes 5% uncalibrated gain ±250 mV offset Offset Voltage TC ±0.5 mV/°C CT Gain 1.05 V/V CT Gain derived from measurements at DAC Code 0x4000 (0.0 V) and DAC Code 0x8CCC (3.0 V); based on an ideal DAC transfer function (see Table 24) Hysteresis 140 mV CT Hysteresis is only applied coming out of alarm Overvoltage Alarm Low, OVDL Functional Voltage Range −2.0 +4.0 V D OVDH DAC set to DAC Code 0xFFFF (7.5 V) Uncalibrated Error at −2.0 V −350 +150 mV P Includes 5% uncalibrated gain ±250 mV offset Uncalibrated Error at 4.0 V −50 +450 mV P Includes 5% uncalibrated gain ±250 mV offset Offset Voltage TC ±0.5 mV/°C CT Gain 1.05 V/V CT Gain derived from measurements at DAC Code 0x4000 (0.0 V) and DAC Code 0x8CCC (3.0 V); based on an ideal DAC transfer function (see Table 24) Hysteresis 140 mV CT Hysteresis is only applied coming out of alarm Thermal Alarm Setpoint Error ±10 °C CT Relative to default alarm value, TJ = 100°C Thermal Hysteresis 15 °C CT |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |