| поискавой системы для электроныых деталей |
|
AD9864-EBZ датащи(PDF) 24 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9864-EBZ датащи(HTML) 24 Page - Analog Devices |
|
24 / 48 page ![]() Data Sheet AD9864 Rev. A | Page 23 of 47 I15 I14 tCLK tHI tV tDV tLOW CLKOUT FS DOUT Figure 34. SSI Timing Parameters for SSI Timing In Figure 34, the timing parameters also apply to inverted CLKOUT or FS modes, with tDV relative to the falling edge of the CLK and/or FS. The AD9864 also provides the means for controlling the switching characteristics of the digital output signals via the drive strength (DS) field of the SSICRB. This feature is useful in limiting switching transients and noise from the digital output that may ultimately couple back into the analog signal path, potentially degrading the sensitivity performance of the AD9864. Figure 35 and Figure 36 show how the NF can vary as a function of the SSI setting for an IF frequency of 109.65 MHz. The following two observations can be made from these figures: 1. The NF becomes more sensitive to the SSI output drive strength level at higher signal bandwidth settings. 2. The NF is dependent on the number of bits within an SSI frame that become more sensitive to the SSI output drive strength level as the number of bits is increased. Therefore, select the lowest possible SSI drive strength setting that still meets the SSI timing requirements. SSI OUTPUT DRIVE STRENGTH SETTING 2 10.0 4 9.6 3 1 8.0 7 6 5 24-BIT I/O DATA 9.8 9.4 9.2 9.0 8.6 8.8 8.4 8.2 16-BIT I/0 DATA w/ DVGA ENABLED 16-BIT I/O DATA Figure 35. NF vs. SSI Output Drive Strength (VDDx = 3.0 V, fCLK = 18 MSPS, BW = 10 kHz) SSI OUTPUT DRIVE STRENGTH SETTING 2 14 4 12 3 1 7 7 6 5 24-BIT I/O DATA 13 11 9 10 8 16-BIT I/O DATA w/DVGA ENABLED 16-BIT I/O DATA Figure 36. NF vs. SSI Output Drive Strength (VDDx = 3.0 V, fCLK = 18 MSPS, BW = 75 kHz) Table 15 lists the typical output rise/fall times as a function of DS for a 10 pF load. Rise/fall times for other capacitor loads can be determined by multiplying the typical values presented by a scaling factor equal to the desired capacitive load divided by 10 pF. Table 15. Typical Rise/Fall Times (±25%) with a 10 pF Capacitive Load for Each DS Setting DS Typ (ns) 0 13.5 1 7.2 2 50 3 3.7 4 3.2 5 2.8 6 2.3 7 2.0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |