| поискавой системы для электроныых деталей |
|
MFC2000 датащи(PDF) 223 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
MFC2000 датащи(HTML) 223 Page - List of Unclassifed Manufacturers |
|
223 / 426 page ![]() Hardware Description MFC 2000 Multifunctional Peripheral Controller 2000 100723A Conexant 9-11 Bi-level Resolution Conversion Control Register: Address: Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Default: Bi-level Res. Conversion Control (BiResConCtrl) 01FF807F (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) Flush FIFO (W) Flush Status (R) Rst Value xxxxxxx0b Read Value 00h Address: Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default: Bi-level Res. Conversion Control (BiResConCtrl) 01FF807E Expansion Mode 0 = 100% ≤ X < 200% 1 = 200% ≤ X < 300% 2 = 300% ≤ X < 400% ORing Threshold Setting 0= no threshold 1-7= threshold value 1-7 Data Source Selection 0=T4/T6 1=Ext. Mem. New line Write 1 and then, 0 " convert a new line Enable Or of orig. line buffer with current scan line Rst Value 00h Read Value 00h Bit 8 For write, 1 " flush FIFO. For read, 1 " flush needed. Bit 7-6 These two bits sets the resolution conversion hardware’s expansion range. If the value of these two bits is ‘n’ and the expected expansion ratio is X, the ratio ‘X-(n* 100%)’ needs to be set into the BiResConRatio register. Bit 5-3 n = the threshold value for the ORing function, n = 0-7. It means that Oring is done to (n+1) contiguous 1’s only when bit 0 is set to 1. Bit 2 Data Source selection When this bit is set to 0, data is serially from the T4/T6 decompressor. When this bit is set to 1, data is from the external memory through the DMA operation (DMA channel 9). Bit 1 Convert a new line Resolution Conversion Logic is reset. Firmware needs to write a 1 and then, immediately write a 0 to tell hardware to convert a new line. Bit 0 Enable OR of orig. line buffer with current scan line (ScanOrEnb) (This bit is only used when the external scan device is selected as the data source of the resolution conversion). 1 = enable Bi-level Vertical OR'ing of the scanner line buffer data. This bit can be used to accomplish normal mode OR'ing and vertical reduction. Note: If you don’t want to do image expansion or image reduction, the resolution conversion ratio is 100%. You need to program bits[7:6] of the BiResConCtrl register to ‘00b’ and program the BiResConRatio register to ‘0000h’. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |