| поискавой системы для электроныых деталей |
|
MFC2000 датащи(PDF) 225 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
MFC2000 датащи(HTML) 225 Page - List of Unclassifed Manufacturers |
|
225 / 426 page ![]() Hardware Description MFC 2000 Multifunctional Peripheral Controller 2000 100723A Conexant 9-13 First Black Data: Address: Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Default: The First Black Data Location Count (FirstBlkDatCnt) $01FF806D (Not Used) (Not Used) (Not Used) (Not Used) data bit 11 data bit 10 data bit 9 data bit 8 Rst Value xxxx0000b Read Value 00h Address: Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default: The First Black Data Location Count (FirstBlkDatCnt) $01FF806C data bit 7 data bit 6 data bit 5 data bit 4 data bit 3 data bit 2 data bit 1 data bit 0 Rst Value 00000000b Read Value 00h Bit 11-0 The First Black Data Location Gives the half word count that black data first appeared in output of the BRC. If the first half word contains black data the register will remain at 000H. If the second half word contains data the register will contain 0001H Etc. If black data in not present in the entire line (all white line), register will be equal to the line length. First Half Word Location = Register Value + 1. Note: Starting a new line will reset the counter Last Black Data: Address: Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Default: The Last Black Data Location Count (LastBlkDatCnt) $01FF806F (Not Used) (Not Used) (Not Used) (Not Used) data bit 11 data bit 10 data bit 9 data bit 8 Rst Value xxxx0000b Read Value 00h Address: Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default: The Last Black Data Location Count (LastBlkDatCnt) $01FF806E data bit 7 data bit 6 data bit 5 data bit 4 data bit 3 data bit 2 data bit 1 data bit 0 Rst Value 00000000b Read Value 00h Bit 11-0 The Last Black Data Location Gives the half word count that black data last appeared in output of the BRC. If black data in not present in the entire line (all white line), register will read 000H. If only the first half word contains black data the register will read 001H. If the second half word contains data the register will contain 0002H Etc. If the last half word contains black data the register will be equal to the total number of half words out of the BRC for that line. Last Half Word Location = Register Value. Note: Starting a new line will reset the counter |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |