| поискавой системы для электроныых деталей |
|
MPC823 датащи(PDF) 34 Page - Motorola, Inc |
|
|
|||||||||||||||||||||||||||||
MPC823 датащи(HTML) 34 Page - Motorola, Inc |
|
34 / 74 page ![]() Communication Processor Module 16-412 MPC823 REFERENCE MANUAL MOTOROLA 16.11.7.6 SMCx TRANSPARENT CONTROLLER PARAMETER RAM MEMORY MAP. There is no protocol-specific parameter RAM for the SMCx Transparent controller. Only the general SMCx parameter RAM is used. See Section 16.11.4 SMC General Parameter RAM Memory Map for more information. 16.11.7.7 SMCx TRANSPARENT COMMANDS. You can program the CPCR (described in Section 16.2.6.1 CPM Command Register) with the following commands to transmit data. • STOP TRANSMIT—After the hardware or software is reset and the channel is enabled in the SMCM–Transparent register, the channel is in transmit enable mode and starts polling the first buffer descriptor in the table. This command disables the transmission of frames on the transmit channel. If the transparent controller receives this command while transmitting a frame, it stops after the contents of the FIFO are transmitted (up to 2 characters). The TBPTR is not advanced to the next buffer descriptor, no new buffer descriptor is accessed, and no new buffers are transmitted for this channel. The transmitter sends idles until the RESTART TRANSMIT command is issued. • RESTART TRANSMIT—This command is used to begin or continue transmission from the current TBPTR in the channel’s TX buffer descriptor table. When the channel receives this command, it starts polling the R bit in the TX buffer descriptor. A serial management controller expects this command after a STOP TRANSMIT command is issued and the channel in the SMCMR is disabled or after a transmitter error occurs. • INIT TX PARAMETERS—This command initializes all the transmit parameters in this serial channel parameter RAM to their reset state and must only be issued when the transmitter is disabled. The INIT TX AND RX PARAMS command can also be used to reset the transmit and receive parameters. You can program the CPCR with the following commands to receive data. • ENTER HUNT MODE—This command forces a serial management controller to close the current receive buffer descriptor if it is currently being used and to use the next buffer descriptor in the list for any subsequently received data. If a serial management controller is not in the process of receiving data, the buffer is not closed. Additionally, this command causes the receiver to wait for a resynchronization before further reception continues. • CLOSE RX BD—This command is used to force a serial management controller to close the current receive buffer descriptor if it is being used and to use the next buffer descriptor in the list for any subsequently received data. If a serial management controller is not in the process of receiving data, no action is taken by this command. • INIT RX PARAMETERS—This command initializes all the receive parameters in this serial channel’s parameter RAM to their reset state. It must only be issued when the receiver is disabled. The INIT TX AND RX PARAMS command can also be used to reset the receive and transmit parameters. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |