49 / 94 page ![]() Monitoring the Bus Some vehicles use the OBD bus for information transfer during normal vehicle operation, passing a great deal of information over it. A lot can be learned if you have the good fortune to connect to one of these vehicles, and are able to decipher the contents of the messages. To see how your vehicle uses the OBD bus, you can enter the ELM327’s ‘Monitor All’ mode, by sending the command AT MA from your terminal program. This will cause the IC to display any information that it sees on the OBD bus, regardless of transmitter or receiver addresses (it will show all). Note that the ELM327 remains silent while monitoring, so periodic ‘wakeup’ messages are not sent (if you have an ISO 9141 or ISO 14230 bus that had been initialized previously, it may ‘go to sleep’), IFRs are not sent, and the CAN module does not acknowledge messages. The monitoring mode can be stopped by putting a logic low level on the RTS pin, or by sending a single RS232 character to the ELM327. Any convenient character can be used to interrupt the IC – there are no restrictions on whether it is printable, etc. Note that any character that you send will be discarded, and will have no effect on any subsequent commands. The time it takes to respond to such an interrupt will depend on what the ELM327 is doing when the character is received. The IC will always finish a task that is in progress (printing a line, for example) before printing ‘STOPPED’ and returning to wait for your input, so it is best to wait for the prompt character (‘>’) to be sent, or the Busy line to go low, before beginning to send a new command. One unexpected result may occur if you have the automatic protocol search feature enabled, and you tell the ELM327 to begin monitoring. If the bus is quiet, the ELM327 will begin searching for an active protocol, which may not be what you were expecting. Be aware also that the ISO 9141 and ISO 14230 protocols look identical when monitoring, so the ELM327 may stop searching at ISO 9141, even if the actual protocol is ISO 14230. With the Automatic searching enabled, this should correct itself, however, when an OBD request is later made. If the ‘Monitor All’ command provides too much information (it certainly does for most CAN systems), then you can restrict the range of data that is to be displayed. Perhaps you only want to see messages that are being transmitted by the ECU with address 10. To do that, you only need to type: >AT MT 10 and all messages that contain 10 in the third byte of the header will be displayed. Using this command with 11 bit CAN systems can be a little confusing at first. Recall the way in which all header bytes are stored within the ELM327. An 11 bit CAN ID is actually stored as the least significant 11 bits in the 3 byte ‘header storage’ location. It will be stored with 3 bits in the receiver’s address location, and the remaining 8 bits in the transmitter’s address location. For this example, we have requested that all messages created by transmitter ‘10’ be printed, so all 11 bit CAN IDs that end in 10 will be displayed (ie all that look like ‘x10’). The other monitoring command that is very useful is the AT MR command, which looks for specific addresses in the middle byte of the header. Using this command, you can look for all messages being sent to a particular address. For example, to use it to look for messages being sent to the ECU with address 10, simply send: >AT MR 10 and all messages that contain 10 in the second byte of the header will be displayed. Using this command with the 11 bit CAN systems will again need further explanation. It may be helpful to first picture the hex number ‘10’ in the above example as the binary number ‘0001 0000’. Recall from above that 11 bit CAN IDs are actually stored as the least significant 11 bits in the 3 byte ‘header storage’ locations, and only 3 bits are actually stored in the middle byte (receiver’s address) position. When comparing the received CAN ID to the address you provide with the MR command then, only the right- most 3 bits of your MR address are considered and the other 5 bits are ignored. In this example, the AT MR 10 effectively becomes AT MR 0 for 11 bit CAN systems, and so all messages that begin with ‘0’ as the first digit will be displayed. It is best not to use the AT MT or MR commands when monitoring CAN systems. The ELM327 provides another command (AT CRA) that allows much better control over the received data - see the next section for complete details. 49 of 94 ELM327L DSA Elm Electronics – Circuits for the Hobbyist www.elmelectronics.com ELM327L |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |