| поискавой системы для электроныых деталей |
|
PCM1602 датащи(PDF) 28 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
PCM1602 датащи(HTML) 28 Page - Texas Instruments |
|
28 / 29 page ![]() PCM1602 28 SBAS163 KEY PERFORMANCE PARAMETERS AND MEASUREMENT This section provides information on how to measure key dynamic performance parameters for the PCM1602. In all cases, an Audio Precision System Two Cascade or equiva- lent audio measurement system is utilized to perform the testing. TOTAL HARMONIC DISTORTION + NOISE Total Harmonic Distortion + Noise (THD+N) is a significant figure of merit for audio DACs, since it takes into account both harmonic distortion and all noise sources within a specified measurement bandwidth. The true rms value of the distortion and noise is referred to as THD+N. The test setup for THD+N measurements is shown in Figure 21. For the PCM1602 DACs, THD+N is measured with a full- scale, 1kHz digital sine wave as the test stimulus at the input of the DAC. The digital generator is set to a 24-bit audio word length and a sampling frequency of 44.1kHz, or 96kHz. The digital generator output is taken from the unbalanced S/PDIF connector of the measurement system. The S/PDIF data is transmitted via coaxial cable to the digital audio receiver on the DEM-DAI1602 demo board. The receiver is then configured to output 24-bit data in either I2S or left-justified data format. The DAC audio interface format is programmed to match the receiver output format. The analog output is then taken from the DAC post filter and connected to the analog analyzer input of the measurement system. The analog input is band-limited, using filters resi- dent in the analyzer. The resulting THD+N is measured by the analyzer and displayed by the measurement system. FIGURE 21. Test Setup for THD+N Measurements. S/PDIF Receiver Evaluation Board f –3dB = 54kHz PCM1602 DEM-DAI1602 2nd-Order Low-Pass Filter Notch Filter Band Limit HPF = 22Hz(1) LPF = 30kHz(1) f C = 1kHz rms Mode 100% Full-Scale 24-Bit, 1kHz Sine Wave S/PDIF Output Option = 20kHz Apogee Filter(2) Analyzer and Display Digital Generator NOTES: (1) There is little difference in measured THD+N when using the various settings for these filters. (2) Required for THD+N test. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |