| поискавой системы для электроныых деталей |
|
TMS320VC549 датащи(PDF) 34 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMS320VC549 датащи(HTML) 34 Page - Texas Instruments |
|
34 / 118 page ![]() TMS320C54x, TMS320LC54x, TMS320VC54x FIXED-POINT DIGITAL SIGNAL PROCESSORS SPRS039C – FEBRUARY 1996 – REVISED DECEMBER 1999 34 POST OFFICE BOX 1443 • HOUSTON, TEXAS 77251–1443 software-programmable PLL (’545A, ’546A, ’548, and ’549) (continued) Immediately following reset, the clock mode is determined by the values of the three external pins: CLKMD1, CLKMD2, and CLKMD3. The modes corresponding to the CLKMD pins are shown in Table 6. Table 6. Clock Mode Settings at Reset CLKMD1 CLKMD2 CLKMD3 CLKMD REGISTER RESET VALUE CLOCK MODE 0 0 0 0000h Divide-by-two, with external source 0 0 1 1000h Divide-by-two, with external source 0 1 0 2000h Divide-by-two, with external source 1 0 0 4000h Divide-by-two, internal oscillator enabled 1 1 0 6000h Divide-by-two, with external source 1 1 1 7000h Divide-by-two, internal oscillator enabled† 1 0 1 0007h PLL × 1 with external source 0 1 1 — Stop mode † Reserved mode (’549 only). Do not use in normal operation. Following reset, the software-programmable PLL can be programmed to any configuration desired, as described above. Note that when the PLL × 1 with external source option (CLKMD[1–3]=101) is selected during reset, the internal PLL lock-count timer is not active; therefore, the system must delay releasing reset in order to allow for the PLL lock-time delay. Also, note that both the hardware- and the software-programmable PLLs require the device to be reset after power up to begin functioning properly. programming considerations when using the software-programmable PLL The software-programmable PLL offers many different options in startup configurations, operating modes, and power-saving features. Programming considerations and several software examples are presented here to illustrate the proper use of the software-programmable PLL at start-up, when switching between different clocking modes, and before and after IDLE1/IDLE2/IDLE3 instruction execution. use of the PLLCOUNT programmable lock timer During the lockup period, the PLL should not be used to clock the ’54x. The PLLCOUNT programmable lock timer provides a convenient method of automatically delaying clocking of the device by the PLL until lock is achieved. The PLL lock timer is a counter, loaded from the PLLCOUNT field in the CLKMD register, that decrements from its preset value to 0. The timer can be preset to any value from 0 to 255, and its input clock is CLKIN divided by 16. The resulting lockup delay can therefore be set from 0 to 255 16 CLKIN cycles. The lock timer is activated when the clock generator operating mode is switched from DIV to PLL (see the section describing switching from DIV mode to PLL mode). During the lockup period, the clock generator continues to operate in DIV mode; after the PLL lock timer has decremented to zero, the PLL begins clocking the ’54x. Accordingly, the value loaded into PLLCOUNT is chosen based on the following relationship: PLLCOUNT > Lockup Time / (16 tCLKIN) where tCLKIN is the input reference clock period and lockup time is the required PLL lockup time as shown in Figure 8. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |