| поискавой системы для электроныых деталей |
|
XC164CS датащи(PDF) 52 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
XC164CS датащи(HTML) 52 Page - Infineon Technologies AG |
|
52 / 71 page ![]() XC164 Derivatives Electrical Parameters Data Sheet 48 V2.1, 2003-06 Configuration pull-down current10) ICPDL 8) –10 µA VIN = VILmax ICPDH 9) 120 – µA VIN = VIHmin Level inactive hold current11) ILHI 8) –-10 µA VOUT = 0.5 × V DDP Level active hold current11) ILHA 9) -100 – µA VOUT = 0.45 V XTAL1 input current IIL CC – ±20 µA0 V < V IN < VDDI Pin capacitance12) (digital inputs/outputs) CIO CC – 10 pF 1) Keeping signal levels within the limits specified in this table, ensures operation without overload conditions. For signal levels outside these specifications, also refer to the specification of the overload current IOV. 2) This parameter is tested for P2, P3, P4, P9. 3) The maximum deliverable output current of a port driver depends on the selected output driver mode, see Table 12, Current Limits for Port Output Drivers. The limit for pin groups must be respected. 4) As a rule, with decreasing output current the output levels approach the respective supply level ( VOL→VSS, VOH→VDDP). However, only the levels for nominal output currents are guaranteed. 5) This specification is not valid for outputs which are switched to open drain mode. In this case the respective output will float and the voltage results from the external circuitry. 6) An additional error current ( IINJ) will flow if an overload current flows through an adjacent pin. Please refer to the definition of the overload coupling factor KOV. 7) This specification is valid during Reset for configuration on RD, WR, EA, PORT0. 8) The maximum current may be drawn while the respective signal line remains inactive. 9) The minimum current must be drawn to drive the respective signal line active. 10) This specification is valid during Reset for configuration on ALE. 11) This specification is valid during Reset for pins P4.3-0, which can act as CS outputs. 12) Not 100% tested, guaranteed by design and characterization. DC Characteristics (cont’d) (Operating Conditions apply)1) Parameter Symbol Limit Values Unit Test Condition min. max. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |