21 / 28 page ![]() 21 LTC1418 APPLICATIONS INFORMATION THREE STATE BUFFER THREE STATE BUFFER 23 RD 17 • • • SCLK* CS 25 EXTCLKIN* 16 EXT/INT* BUSY *PINS 16 TO 20 ARE LABELED WITH THEIR SERIAL FUNCTIONS 1418 F20 20 DOUT* 19 CLKOUT* 18 26 SHIFT REGISTER INTERNAL CLOCK 16 CONVERSION CLOCK CYCLES EOC DATA IN 14 DATA OUT CLOCK INPUT • • • SAR Figure 20. Functional Block Diagram for Serial Mode (SER/PAR = High) asynchronous clocks. To maintain accuracy the external conversion clock frequency must be between 30kHz and 4.5MHz.) The SAR sends an end of conversion signal, EOC, that gates the external conversion clock so that only 16 clock cycles can go into the SAR, even if the external clock, EXTCLKIN, contains more than 16 cycles. When CS and RD are low, these 16 cycles of conversion clock (whether internally or externally generated) will appear on CLKOUT during each conversion and then CLKOUT will remain low until the next conversion. If desired, CLKOUT can be used as a master clock to drive the serial port. Because CLKOUT is running during the conversion, it is important to avoid excessive loading that can cause large supply transients and create noise. For the best performance, limit CLKOUT loading to 20pF. Serial Port The serial port in Figure 20 is made up of a 16-bit shift register and a three-state output buffer that are con- trolled by three inputs: SCLK, RD and CS. The serial port has one output, DOUT, that provides the serial output data. The SCLK is used to clock the shift register. Data may be clocked out with the internal conversion clock operating as a master by connecting CLKOUT (Pin 18) to SCLK (Pin 17) or with an external data clock applied to D3 (SCLK). The minimum number of SCLK cycles required to transfer a data word is 14. Normally, SCLK contains 16 clock cycles for a word length of 16 bits; 14 bits with MSB first, followed by two trailing zeros. A logic high on RD disables SCLK and three-states DOUT. In case of using a continuous SCLK, RD can be controlled to limit the number of shift clocks to the desired number (i.e., 16 cycles) and to three-state DOUT after the data transfer. A logic high on CS three-states the DOUT output buffer. It also inhibits conversion when it is tied high. In power shutdown mode (SHDN = low), a high CS selects sleep mode while a low CS selects nap mode. For normal serial port operation, CS can be grounded. DOUT outputs the serial data; 14 bits, MSB first, on the falling edge of each SCLK (see Figures 21 and 22). If 16 SCLKs are provided, the 14 data bits will be followed by |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |