46 / 53 page ![]() Motor control operations UM0432 46/53 Note: Turning the P3 potentiometer modifies the "phase shift" parameter. To optimize driving, the correct value of this parameter must be set. Finding the optimum value of the "phase shift" can be useful to monitor the DC current provided by the power supply. You should try to fine-tune the P3 potentiometer to minimize current absorption. When this parameter has been found, the potentiometer P3 can be left at this value for all future tests. During any state: idle, start, run or brake, a blinking red LED indicates a fault condition. A fault condition is due to one of the following: ● hardware overcurrent: current flowing inside the motor reaches a value greater than the maximum allowed current of 7.65 A (see Section 7.4.16). ● Over-voltage: the bus voltage reaches a value greater than 29 Vac. ● Over-temperature: the on-board temperature sensor measures a temperature greater than 110° C. ● Start-up failed: no signal is received from the sensors at the end of the start-up sequence. ● Motor stalled: during the running of the motor no sensor signal has been observed. 7.7.6 Changing the real-time parameters The real-time parameters can be changed using the control board’s potentiometers. Table 22 explains the potentiometer functionality based on the driving strategy. If during the GUI configuration phase the "set phase shift according to Pf/F curve" control was checked, the value of the "phase shift" is not set by P3 but is calculated at run-time based on the Pf/F curve (see Section 7.4.7). The maximum current allowed by the GUI has been set to 8 A (see Section 7.4.8). 7.7.7 Stopping the motor (LED action) Push the Start/Stop button to stop the motor. The LEDs toggle from green to red to indicate an "idle" state. Table 22. Potentiometer functionality based on an open-/closed-loop driving strategy Open loop Closed loop P1 Sets the voltage modulation index from 0% to 100% of the bus voltage. Sets the target rotor frequency value from the minimum value to the maximum value configured (see Section 7.4.6). P2 Not used P3 Manual setting of the phase shift. The maximum CCW position is 0° of the phase shift and the maximum CW position is 360° of the phase shift. P4 Not used |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |