| поискавой системы для электроныых деталей |
|
UM0432 датащи(PDF) 43 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
UM0432 датащи(HTML) 43 Page - STMicroelectronics |
|
43 / 53 page ![]() UM0432 Motor control operations 43/53 After power-on, the control board’s green LED should blink, signaling that the firmware has started to run. After a while a green LED stays on indicating an "idle" state. 7.6.4 Setting the potentiometers Before running the motor, the three potentiometers P1, P2, P3 must be set (see Table 19 for the correct configuration). 7.6.5 Running the motor (LED action) Push the Start/Stop button. After pushing the button the LEDs toggle from green to red to indicate a "run" state. The motor starts running. During any state: idle, start, run or brake, a still red LED together with the brake of the motor indicates a fault condition. A fault condition is due to one of the following: ● hardware overcurrent: current flowing inside the motor reaches a value greater than the maximum allowed current of 7.65 A (see Section 7.4.16). ● Over-voltage: the bus voltage reaches a value greater than 29 Vac. ● Over-temperature: the on-board temperature sensor measures a temperature greater than 110° C. ● Start-up failed: the start-up phase ends without getting a sufficient number of valid zero crossing events. ● Motor stalled: during the running of the motor no zero crossing events have been observed. Note: Blinking of the red LED during the running of the motor indicates that a software current limitation is in action. 7.6.6 Changing the real-time parameters The real-time parameters can be changed using the control board’s potentiometers. Table 19 explains the potentiometer functionality based on the driving strategy. Table 19. Potentiometer functionality based on open/closed loop driving strategy Voltage mode Open Loop Closed loop P1 Sets the duty cycle percentage from 0% to 100%. Sets the target rotor frequency value from the minimum value to the maximum value configured (see Section 7.4.4). P2 Sets the value of the rising delay coefficient from 0 to 255 P3 Sets the value of the falling delay coefficient from 0 to 255 P4 Not used Current mode Open loop Closed loop P1 Sets the current reference value from 0 A to the maximum current allowed. Sets the target rotor frequency value from the minimum value to the maximum value configured (see Section 7.4.4). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |