| поискавой системы для электроныых деталей |
|
AM79C976 датащи(PDF) 183 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C976 датащи(HTML) 183 Page - Advanced Micro Devices |
|
183 / 309 page ![]() 8/01/00 Am79C976 183 P R E L I M INARY is not affected by S_RESET or setting the STOP bit. 6 MAPINTE MII Auto-Poll Interrupt Enable. If MAPINTE is set, the MAPINT bit will be able to set the INTR bit. Read/Write accessible. MAP- INTE is set to 0 by H_RESET and is not affected by S_RESET or setting the STOP bit 5 MCCINT MII Management Command Complete Interrupt. The MII Man- agement Command Complete In- terrupt is set by the Am79C976 controller when a read or write operation to the MII Data Port (BCR34) is complete. When MCCINT is set to 1, INTA is asserted if the enable bit MCCINTE is set to 1. Read/Write accessible. MCCINT is cleared by the host by writing a 1. Writing a 0 has no effect. MCCINT is cleared by H_RESET and is not affected by S_RESET or setting the STOP bit. 4 MCCINTE MII Management Command Complete Interrupt Enable. If MCCINTE is set to 1, the MCCINT bit will be able to set the INTR bit when the host reads or writes to the MII Data Port (BCR34) only. Internal MII Man- agement Commands will not gen- erate an interrupt. For instance, Auto-Poll state machine generat- ed MII management frames will not generate an interrupt upon completion unless there is a com- pare error which gets reported through the MAPINT (CSR7, bit 6) interrupt or the MCCIINTE is set to 1. Read/Write accessible. MC- CINTE is set to 0 by H_RESET and is not affected by S_RESET or setting the STOP bit. 3 MCCIINT MII Management Command Complete Internal Interrupt. The MII Management Command Complete Interrupt is set by the Am79C976 controller when a read or write operation on the MII management port is complete from an internal operation. Exam- ples of internal operations are Auto-Poll or MII Management Port generated MII management frames. These are normally hid- den to the host. When MCCIINT is set to 1, INTA is asserted if the enable bit MCCINTE is set to 1. Read/Write accessible. MCCIINT is cleared by the host by writing a 1. Writing a 0 has no effect. MCCIINT is cleared by H_RESET and is not affected by S_RESET or setting the STOP bit. 2 MCCIINTE MII Management Command Complete Internal Interrupt En- able. If MCCIINTE is set to 1, the MCCIINT bit will be able to set the INTR bit when the internal state machines generate MII management frames. For in- stance, when MCCIINTE is set to 1 and the Auto-Poll state ma- chine generates a MII manage- ment frame, the MCCIINT will set the INTR bit upon completion of the MII management frame re- gardless of the comparison out- come. Read/Write accessible. MCCIINTE is set to 0 by H_RESET and is not affected by S_RESET or setting the STOP bit. 1 MIIPDTINT MII PHY Detect Transition Inter- rupt. The MII PHY Detect Transi- tion Interrupt is set by the Am79C976 controller whenever the MIIPD bit (BCR32, bit 14) transitions from 0 to 1 or vice ver- sa. Read/Write accessible. MIIP- DTINT is cleared by the host by writing a 1. Writing a 0 has no ef- fect. MIIPDTINT is cleared by H_RESET and is not affected by S_RESET or setting the STOP bit. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |