| поискавой системы для электроныых деталей |
|
APW8811 датащи(PDF) 5 Page - Anpec Electronics Coropration |
|
|
|||||||||||||||||||||||||||||
APW8811 датащи(HTML) 5 Page - Anpec Electronics Coropration |
|
5 / 23 page ![]() Copyright © ANPEC Electronics Corp. Rev. A.3 - Sep., 2012 APW8811 www.anpec.com.tw 5 Electrical Characteristics (Cont.) APW8811 Symbol Parameter Test Conditions Min. Typ. Max. Unit PWM CONTROLLERS (CONT.) UGATEx Minimum On-Time 80 110 140 ns Minimum Ultrasonic SKIP Operating Frequency 25 37 - kHz LOW DROUPUT LINEAR REGULATORS (LDO5/LDO3) LDO5 Output Voltage VOUT1 = GND, 6V < VIN < 25V, 0< ILDO < 100mA 4.8 5.0 5.2 V LDO3 Output Voltage VOUT2 = GND, 6V < VIN < 25V, 0< ILDO3 < 100mA 3.2 3.33 3.46 V VOUT1 Regulation Voltage Rising 4.55 4.7 4.85 VTHBYP5 LDO5 Bypass Threshold for VOUT1-to-LDO5 Switch On Hysteresis 0.15 0.25 0.3 V VOUT2 Regulation Voltage Rising 3.05 3.15 3.25 VTHBYP3 LDO3 Bypass Threshold for VOUT2-to-LDO3 Switch On Hysteresis 0.1 0.2 0.25 V VOUTx-to-LDOx Switch On Resistance VOUTx to LDOx, 10mA - 1.5 3 Ω LDOx Current-Limit VOUTx = GND, LDOx = GND 150 - - mA LDOx Discharge On Resistance - 40 65 Ω REFFERENCE REF Output Voltage IREF = 0A 1.98 2.00 2.02 V REF Load Regulation ILOAD = 0 to 50 µA - 10 - mV REF Sink Current REF in Regulation 10 - - µA PWM 1/2 PROTECTIONS Over-Voltage Protection Threshold VOUTX RIsing 120 125 130 % Over-Voltage Fault Propagation Delay Delta voltage = 10mV - 1.5 - µs VILIM = 920mV, TA = 25 oC 9.4 10 10.6 µA Current-Limit Current Source On the basis of 25 oC - 4500 2 ppm/ oC ILIMx Adjustment Range VILIMx-GND 0.515 - 2 V Maximum setting voltage VILIMx= 5V, Setting Current-Limit Threshold 205 250 - mV Current-limit comparator offset (VILIMx-GND-VPGND-PHASEx), VILIMx = 920mV -8 0 8 mV Zero-Crossing Threshold SKIP# = REF or LDOx, VPGND-PHASE -5 0 5 mV Under-Voltage Protection Threshold 65 70 75 % Under-Voltage Protection Hysteresis - 3 - % Under-Voltage Protection Debounce Interval 22 32 42 µs Under-Voltage Protection Enable Blanking Time From EN signal go high to UVP workable - 2 2.6 ms TJ Rising - 160 - Over-Temperature Protection THreshold Hysteresis - 25 - oC Refer to the typical application circuits. These specifications apply over V IN=12V and TA= -40 ~ 85 °C, unless otherwise specified. Typical values are at T A=25°C. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |