17 / 24 page ![]() Data Sheet AD5232 Rev. C | Page 17 of 24 ADVANCED CONTROL MODES The AD5232 digital potentiometer contains a set of user program- ming features to address the wide variety of applications avail- able to these universal adjustment devices. Key programming features include the following: • Independently programmable read and write to all registers • Simultaneous refresh of all RDAC wiper registers from corresponding internal EEMEM registers • Increment and decrement command instructions for each RDAC wiper register • Left and right bit shift of all RDAC wiper registers to achieve 6 dB level changes • Nonvolatile storage of the present scratch pad RDACx register values into the corresponding EEMEMx register • Fourteen extra bytes of user-addressable, electrical erasable memory Increment and Decrement Commands The increment and decrement command instructions (Command Instruction 14, Command Instruction 15, Command Instruction 6, and Command Instruction 7) are useful for the basic servo adjust- ment application. These commands simplify microcontroller software coding by eliminating the need to perform a readback of the current wiper position and then add a 1 to the register contents using the microcontroller adder. The microcontroller sends an increment command instruction (Command Instruc- tion 14) to the digital potentiometer, which automatically moves the wiper to the next resistance segment position. The master increment command instruction (Command Instruction 15) moves all potentiometer wipers by one position from their present position to the next resistor segment position. The direction of movement is referenced to Terminal B. Thus, each Command Instruction 15 moves the wiper tap position farther from Terminal B. Logarithmic Taper Mode Adjustment Programming instructions allow decrement and increment wiper position control by an individual potentiometer or in a ganged potentiometer arrangement, where both wiper positions are changed at the same time. These settings are activated by the 6 dB decrement and 6 dB increment command instructions (Command Instruction 4 and Command Instruction 5, and Command Instruction 12 and Command Instruction 13, respectively). For example, starting with the wiper connected to Terminal B, executing nine increment instructions (Command Instruction 12) moves the wiper in 6 dB steps from the 0% of the RBA (Terminal B) position to the 100% of the RBA position of the AD5232 8-bit potentiometer. The 6 dB increment instruction doubles the value of the RDACx register contents each time the command is executed. When the wiper position is greater than midscale, the last 6 dB increment command instruction causes the wiper to go to the full-scale 255 code position. Any addi- tional 6 dB instruction does not change the wiper position from full scale (RDACx register code = 255). Figure 37 illustrates the operation of the 6 dB shifting function on the individual RDACx register data bits for the 8-bit AD5232 example. Each line going down the table represents a successive shift operation. Note that the Left Shift 12 and Left Shift 13 com- mand instructions were modified so that if the data in the RDACx register is equal to 0 and is left shifted, it is then set to Code 1. In addition, the left shift commands were modified so that if the data in the RDAC register is greater than or equal to midscale and is left shifted, the data is then set to full scale. This makes the left shift function as close to ideally logarithmic as possible. The Right Shift 4 and Right Shift 5 command instructions are ideal only if the LSB is 0 (that is, ideal logarithmic, with no error). If the LSB is a 1, the right shift function generates a linear half- LSB error that translates to a code-dependent logarithmic error for odd codes only, as shown in Figure 38. The plot shows the errors of the odd codes. LEFT SHIFT 0000 0000 0000 0001 0000 0010 0000 0100 0000 1000 0001 0000 0010 0000 0100 0000 1000 0000 1111 1111 1111 1111 RIGHT SHIFT 1111 1111 0111 1111 0011 1111 0001 1111 0000 0111 0000 0011 0000 0001 0000 0000 0000 0000 0000 0000 0000 0000 LEFT SHIFT (+6dB) RIGHT SHIFT (–6dB) Figure 37. Detail Left and Right Shift Function Actual conformance to a logarithmic curve between the data contents in the RDACx register and the wiper position for each Right Shift 4 and Right Shift 5 command execution contains an error only for the odd codes. The even codes are ideal, with the exception of zero right shift or greater than half-scale left shift. Figure 38 shows plots of Log_Error, that is, 20 × log10 (error/code). For example, Code 3 Log_Error = 20 × log10 (0.5/3) = −15.56 dB, which is the worst case. The plot of Log_Error is more signifi-cant at the lower codes. 0 –10 –20 –30 –40 –50 –60 0 20 40 60 80 100 120 140 160 180 200 220 240 260 CODE, FROM 1 TO 255 BY 2 LOG_ERROR (CODE) FOR 8-BIT Figure 38. Plot of Log_Error Conformance for Odd Codes Only (Even Codes Are Ideal) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |